This standard specifies the terms and definitions, product structure, classification and labeling, requirements, test methods, inspection rules and marking, packaging, transportation and storage of self-limiting temperature electric heating tapes for buildings and living facilities. This standard is applicable to self-limiting temperature electric heating belts made of conductive polymer composite materials with resistance-positive temperature coefficients for ground radiant heating, roof snow melting, pavement ice and snow melting, and living facilities.
JC/T 2230-2014 Referenced Document
GB 19518.1-2004 Electrical apparatus for explosive gas atmospheres Electrical resistance trace heating-Part 1:General and testing requirements
GB/T 20841-2007 Heating cables with a rated voltage of 300/500 V for comfort heating and prevention of ice formation
GB/T 2951.11-2008 Common test method for insulating and sheathing materials of electric and optical cables.Part 11:Methods for general application.Measurement of thickness and overall dimensions.Tests for determining the mechanical properties
GB/T 3048.8-2007 Test methods for electrical properties of electric cables and wires.Part 8: AC voltage test
JC/T 2230-2014 history
2014JC/T 2230-2014 Self-regulating heating belts for buildings and living facilities