ASTM E1199-87(2012)
Standard Practice for Sampling Zooplankton with a Clarke-Bumpus Plankton Sampler

Standard No.
ASTM E1199-87(2012)
Release Date
1987
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM E1199-19
Latest
ASTM E1199-24
Scope
1.1 It will sample a discrete depth or multiple depths, depending upon the sampling design.

4.1.2 It is a slow to medium speed sampler requiring a towing speed of three to five knots.

4.1.3 The sample size can be easily controlled.

4.1.4 The sampler is lightweight and can be used without auxiliary equipment.

4.1.5 It has a relatively high filtration efficiency factor of 0.88.

4.1.6 It is a versatile sampler and can be used in all but the shallowest waters.

4.1.7 The flowmeter records the amount of water that passes into the net.

4.1.8 Overspill of water at the mouth of the net due to excess speed of towing is of minimal consequence.

4.2 The disadvantages of the Clarke-Bumpus plankton sampler are as follows:

4.2.1 The flowmeter requires frequent maintenance including calibration and lubrication.

4.2.2 It is not suitable for use in very small areas or shallow waters.

4.3 There are several special considerations that shall be observed when using a Clarke-Bumpus sampler. They are:

4.3.1 The flowmeter should be calibrated and serviced frequently to ensure efficient and accurate operation.

4.3.2 The sampler is relatively fragile, particularly the closing device and flowmeter. This necessitates careful deployment and recovery procedures.

4.3.3 Following each collection, the net must be thoroughly washed.

4.3.4 Special attention must be given to the strength of the cable and its attachment to avoid loss of the sampler.

4.3.5 The sampler should not be used in beds of macrophytes, in waters containing submerged objects, or close to the bottom.

4.3.6 The net should be inspected frequently for pin-size holes, tears, net deterioration, and other anomalies.

4.3.7 Following use, the wet net should be suspended full length in the air in subdued light and allowed to dry.

ASTM E1199-87(2012) Referenced Document

ASTM E1199-87(2012) history

Standard Practice for  Sampling Zooplankton with a Clarke-Bumpus Plankton Sampler



Copyright ©2024 All Rights Reserved