CISPR 16-1-5 Edition 1.1-2012
Specification for radio disturbance and immunity measuring apparatus and methods. Part 1-5: Radio disturbance and immunity measuring apparatus.Specifications and validation procedures for CALTS and REFTS from 30 MHz to 1 000 MHz

Standard No.
CISPR 16-1-5 Edition 1.1-2012
Release Date
2012
Published By
International Electrotechnical Commission (IEC)
Status
Replace By
CISPR 16-1-5-2014
Latest
CISPR 16-1-5-2014
Scope
This part of CISPR 16 specifies the requirements for calibration test sites used to perform antenna calibrations and for reference test sites used to measure the antenna-pair reference site attenuation for compliance test site validations. It describes the test antenna characteristics, calibration and reference test site verification procedures and site compliance criteria. Further information on calibration site requirements, test antenna considerations and the theory of antennas and site attenuation is provided in informative annexes. Measurement instrumentation specifications are given in CISPR 16-1-1 and CISPR 16-1-4. Further information and background on uncertainties in general is given in CISPR 16-4-1, which may be helpful in establishing uncertainty estimates for the calibration processes of antennas.

CISPR 16-1-5 Edition 1.1-2012 Referenced Document

  • CISPR 14-1-2000 Compatibilite Electromagnetique - Exigences Pour Les Appareils Electrodomestiques@ Outillages Electriques Et Appareils Analogues - Partie 1: Emission (Edition 4.0)
  • CISPR 16-1-1-2003 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1:Radio disturbance and immunity measuring apparatus - Measuring apparatus
  • CISPR 16-1-4 Amendment 2 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated dis*2023-04-13 Update
  • CISPR 16-4-1-2003 Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-1:Uncertainties, statistics and limit modelling - Uncertainties in standardized EMC tests
  • CISPR 16-4-2-2003 Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2:Uncertainties,statistics and limit modelling - Uncertainty in EMC measurements

CISPR 16-1-5 Edition 1.1-2012 history

  • 2014 CISPR 16-1-5-2014 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz
  • 2012 CISPR 16-1-5 Edition 1.1-2012 Specification for radio disturbance and immunity measuring apparatus and methods. Part 1-5: Radio disturbance and immunity measuring apparatus.Specifications and validation procedures for CALTS and REFTS from 30 MHz to 1 000 MHz

CISPR 16-1-5 Edition 1.1-2012 Specification for radio disturbance and immunity measuring apparatus and methods. Part 1-5: Radio disturbance and immunity measuring apparatus.Specifications and validation procedures for CALTS and REFTS from 30 MHz to 1 000 MHz was changed to CISPR 16-1-5-2014 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz.

Specification for radio disturbance and immunity measuring apparatus and methods. Part 1-5: Radio disturbance and immunity measuring apparatus.Specifications and validation procedures for CALTS and REFTS from 30 MHz to 1 000 MHz



Copyright ©2024 All Rights Reserved