- Standard No.
- NB/T 20104-2012
- Language
- Chinese, Available in English version
- Release Date
- 2012
- Published By
- Professional Standard - Energy
- Latest
-
NB/T 20104-2012
- Replace
-
EJ/T 779-1993
- Scope
- This standard specifies the criteria, acceptable analysis methods and assumptions that should be followed in the expected transient analysis of a pressurized water reactor nuclear power plant that fails to shut down. This standard is applicable to the analysis of expected transient conditions in which a pressurized water reactor nuclear power plant fails to shut down in an emergency.
NB/T 20104-2012 Referenced Document
- EJ/T 562 Time response design criteria for safety-related operator actions
- NB/T 20035 Categorization of conditions of PWR nuclear power plants
- NB/T 20103 Accident analysis and safety criteria for pressurized water reactor nuclear power plants*, 2023-05-26 Update
NB/T 20104-2012 history
- 2012 NB/T 20104-2012 Analysis requirement for anticipated transient without scram on pressurized water reactor nuclear power plants
- 1993 EJ/T 779-1993 Predicted transient analysis requirements for PWR nuclear power plants that fail to emergency shut down
NB/T 20104-2012 Analysis requirement for anticipated transient without scram on pressurized water reactor nuclear power plants has been changed from EJ/T 779-1993 Predicted transient analysis requirements for PWR nuclear power plants that fail to emergency shut down.