NB/T 20062-2012
Batteries for uninterruptible power supply systems for nuclear power plants (English Version)

Standard No.
NB/T 20062-2012
Language
Chinese, Available in English version
Release Date
2012
Published By
Professional Standard - Energy
Latest
NB/T 20062-2012
Scope
This standard specifies the selection, installation design, installation, maintenance and testing methods of nuclear power plant uninterruptible power supply (UPS) system battery packs, and gives the relationship between UPS battery charging, rectifier devices and battery equipment selection. This standard applies to the selection, installation, maintenance and testing of battery packs for UPS systems in nuclear power plants. This standard does not apply to the design of UPS components, nor does it apply to the backup battery of the DC output rectifier device. This standard divides exis ing batteries into the following three types:  ——vented lead-acid batteries (VLA);  ——valve-regulated lead-acid batteries (VRLA);  ——nickel-cadmium batteries (Ni-Cd). This standard The standard describes the technical characteris ics and design points of each type of battery to facilitate user use.

NB/T 20062-2012 Referenced Document

  • GB/T 12788 Criteria for class 1E power systems for nuclear power plants*2021-08-20 Update
  • GB/T 13286 Criteria for independence of class 1E equipment and circuits in nuclear power plants*2021-12-31 Update
  • GB/T 13625 Seismic qualification of safety class electrical equipment for nuclear power plants*2018-05-14 Update
  • IEEE 1187 Recommended Practice for Installation Design and Installation of Valve-Regulated Lead-Acid Batteries for Stationary Applications*2013-12-11 Update
  • IEEE 1188 Recommended Practice for Maintenance, Testing, and Replacement of Valve-Regulated Lead-Acid (VRLA) Batteries for Stationary Applications
  • NB/T 20028.1 The batteries used in nuclear power plants Part 1: Recommended practice for sizing
  • NB/T 20028.2 The batteries used in nuclear power plants Part 2: Recommended practice for installation design and installation
  • NB/T 20028.4 The batteries used in nuclear power plants Part 4: Recommended practice for maintenance, testing and replancement
  • NB/T 20080 Appraisal of safety-level vented lead-acid batteries in nuclear power plants*2019-12-30 Update

NB/T 20062-2012 history

  • 2012 NB/T 20062-2012 Batteries for uninterruptible power supply systems for nuclear power plants
Batteries for uninterruptible power supply systems for nuclear power plants



Copyright ©2024 All Rights Reserved