VDI 3940 Blatt 2-2006
Measurement of odour impact by field inspection - Measurement of the impact frequency of recognizable odours - Plume measurement

Standard No.
VDI 3940 Blatt 2-2006
Release Date
2006
Published By
Association of German Mechanical Engineers
Latest
VDI 3940 Blatt 2-2006
Replace
VDI 3940-1993 VDI 3940 Blatt 2-2003
Scope
The present guideline is a set of instructions for the measurement of odour impact in an area affected by an odorant plume. The odour load is determined here with qualified assessors who assess the ambient air for odours at previously defined positions within certain measurement cycles. Plume measurements are used for gathering information on odour impact within an odorant plume. The investigation takes place in specific (measured) meteorological conditions. Like for grid field inspections, the percentage time with odour detection (percentage odour time) during a single measurement is used as the measured variable for odour impact. The main field of application of plume measurement is for the reverse calculation of emission source strengths by using suitable dispersion models. Furthermore, it can also be used in the calibration and validation of dispersion models, for the determination of plume extent and in the pinpointing of causers of emissions.

VDI 3940 Blatt 2-2006 Referenced Document

  • DIN 10954:1997 Sensory testing methods - Paired comparison test
  • DIN 10961:1996 Training of assessors for sensory analysis
  • DIN 10962:1997 Areas for sensory analysis - Specifications of testrooms
  • DIN 10963:1997 Sensory testing methods - Ranking method
  • DIN 10964:1996 Sensory testing methods - Simple descriptive test
  • DIN 10966:1997 Sensory testing methods - Intensity test
  • DIN EN 13725:2003 Air quality - Determination of odour concentration by dynamic olfactometry; German version EN 13725:2003
  • VDI 2449 Blatt 2-1987 Basic concepts for characterization of a complete measuring procedure; glossary of terms
  • VDI 3782 Blatt 1-2001 Umweltmeteorologie - Atmosphaerische Ausbreitungsmodelle - Gauss'sches Fahnenmodell fuer Plaene zur Luftreinhaltung
  • VDI 3786 Blatt 1-1995 Environmental meteorology - Meteorological measurements - Fundamentals
  • VDI 3786 Blatt 2-2000 Environmental meteorology - Meteorological measurements concerning questions of air pollution - Wind
  • VDI 3786 Blatt 3-1985 Meteorological measurements concerning questions of air pollution; air temperature

VDI 3940 Blatt 2-2006 history

  • 2006 VDI 3940 Blatt 2-2006 Measurement of odour impact by field inspection - Measurement of the impact frequency of recognizable odours - Plume measurement
  • 2003 VDI 3940 Blatt 2-2003 Determination of odorants in ambient air by field inspections - Determination of the frequency of identifiable odour in ambient air - Plume measurement
  • 1993 VDI 3940-1993 Bestimmung der Geruchsstoffimmission durch Begehungen

VDI 3940 Blatt 2-2006 Measurement of odour impact by field inspection - Measurement of the impact frequency of recognizable odours - Plume measurement has been changed from VDI 3940-1993 Bestimmung der Geruchsstoffimmission durch Begehungen.

Measurement of odour impact by field inspection - Measurement of the impact frequency of recognizable odours - Plume measurement



Copyright ©2024 All Rights Reserved