This part of IEC 61347 specifies particular safety requirements for electronic control gear for use on a.c. and d.c. supplies up to 1 000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply frequency@ associated with fluorescent lamps as specified in IEC 60081 and IEC 60901@ and other fluorescent lamps for high-frequency operation. Performance requirements are the subject of IEC 60929. Particular requirements for electronic control gear with means protection against overheating are given in Annex C. For emergency lighting operation@ particular requirements for control gear operated from a central supply are given in Annex J. Performance requirements appropriate to the safe operation of emergency lighting are also contained in Annex J. Requirements for emergency lighting control gear operating from non-centralised power supplies are given in IEC 61347-2-7. NOTE Performance requirements detailed by Annex J are those considered to be safety-related with respect to reliable emergency operation.
IEC 61347-2-3:2011 history
2016IEC 61347-2-3:2011/AMD1:2016 Lamp control gear - Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps
2016IEC 61347-2-3:2016 Amendment 1 - Lamp control gear - Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps
2011IEC 61347-2-3:2011/COR1:2011 Corrigendum 1 - Lamp control gear - Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps
2011IEC 61347-2-3:2011 Lamp control gear - Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps
1970IEC 61347-2-3:2000/AMD2:2006 Amendment 2 - Lamp controlgear - Part 2-3: Particular requirements for a.c. supplied electronic ballasts for fluorescent lamps
1970IEC 61347-2-3:2000/AMD1:2004 Amendment 1 - Lamp controlgear - Part 2-3: Particular requirements for a.c. supplied electronic ballasts for fluorescent lamps
2004IEC 61347-2-3:2004 Appareillages de lampes – Partie 2-3: Prescriptions particulières pour les ballasts électroniques alimentés en courant alternatif pour lampes fluorescentes (Edition 1.1; Consolidated with Amendment 1:2004)
2000IEC 61347-2-3:2000 Lamp controlgear - Part 2-3: Particular requirements for a.c. supplied electronic ballasts for fluorescent lamps
IEC 61347-2-3:2011 Lamp control gear - Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps has been changed from IEC 60925:1989 D.c. supplied electronic ballasts for tubular fluorescent lamps; performance requirements.
IEC 61347-2-3:2011 Lamp control gear - Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps has been changed from IEC 61347-2-4:2000 Lamp controlgear - Part 2-4: Particular requirements for d.c. supplied electronic ballasts for general lighting.
IEC 61347-2-3:2011 Lamp control gear - Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps has been changed from IEC 61347-2-5:2000 Lamp controlgear - Part 2-5: Particular requirements for d.c. supplied electronic ballasts for public transport lighting.
IEC 61347-2-3:2011 Lamp control gear - Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps has been changed from IEC 61347-2-9:2012 Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps).