General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Latest
GB/T 26142.2-2010
Scope
This part of GB/T 26142 stipulates the following requirements for the installation surface and electrical connectors of pneumatic five-way directional control valves with optional electrical connectors with specifications of 18mm and 26mm and a maximum rated operating pressure of 1.6MPa: the size and shape of the installation surface position tolerance; identification of the main air port and control air port; identification of the control results of the control device; dimensions, tolerances and specifications of optional electrical connectors. This section does not apply to the functional characteristics of the mounting surface.
GB/T 26142.2-2010 Referenced Document
ISO 1101 Geometrical product specifications (GPS) - Geometrical tolerancing - Tolerances of form, orientation, location and run-out*, 2017-02-01 Update
ISO 11727 Pneumatic fluid power - Identification of ports and control mechanisms of control valves and other components
ISO 1302 Geometrical Product Specifications (GPS) — Indication of surface texture in technical product documentation — Amendment 2: Indication of material ratio requirements
ISO 4288 Geometrical Product Specifications (GPS) - Surface texture: Profile method - Rules and procedures for the assessment of surface texture; Technical Corrigendum 1
ISO 5598 Fluid power systems and components — Vocabulary*, 2020-01-06 Update
GB/T 26142.2-2010 history
2011GB/T 26142.2-2010 Pneumatic fluid power.Five-port directional control valves,sizes 18mm and 26mm.Part 2:Mounting interface surfaces with optional electrical connector