JJG 962-2010
Verification Regulation of Personal Dose Equivalent Rate Warning Devices for X and γRadiation (English Version)

Standard No.
JJG 962-2010
Language
Chinese, Available in English version
Release Date
2010
Published By
National Metrological Verification Regulations of the People's Republic of China
Latest
JJG 962-2010
Scope
This procedure is applicable to the initial calibration, follow-up calibration and in-use inspection of acoustic or acousto-optical strong penetrating X and gamma radiation personal dose equivalent rate alarms worn on the human body. The energy range of X and γ radiation is 50 keV ~ 1.5 MeV. If the alarm is to be used to measure the dose equivalent rate produced by photons of higher energy (up to 10 MeV), then its response must be determined at the appropriate energy. This procedure does not apply to the verification of alarm devices with a personal dose equivalent rate of Hp (0.07) for weak penetrating X and γ radiation. This procedure does not apply to the verification of personal alarms for neutron and beta radiation.

JJG 962-2010 history

  • 2010 JJG 962-2010 Verification Regulation of Personal Dose Equivalent Rate Warning Devices for X and γRadiation
  • 2001 JJG 962-2001 Verification Regulation of Personal Warning Devices for X and γ Radiations
Verification Regulation of Personal Dose Equivalent Rate Warning Devices for X and γRadiation