The test procedure per the applicable Engine Manual does require a vibration check for the low/intermediate and high speed rotor systems. Release of an engine with high vibrations can result in: On-wing vibration complaints, with subsequent troubleshooting; Rotorsystem failures; Premature engine removals Limits are provided for transient conditions and steady state data points. Troubleshooting recommendations are limited to verification of the proper signal input and tracking. This practice provides recommendations for: Correct cable and transmitter installation and connections; Calibration; Recorded data interpretation and data analysis
SAE ARP6068-2010 history
2017SAE ARP6068-2017 Gas Turbine Engine Test Facility Vibration Measurement
2010SAE ARP6068-2010 Gas Turbine Engine Test Facility Vibration Measurement