This part specifies the requirements for the design, manufacture, inspection and acceptance of steel welded atmospheric pressure vessels. The scope of application of this section is Cylindrical vessels: The design pressure is greater than -0.02MPa and less than 0.1MPa, and the design temperature range is determined according to the allowable use temperature of steel; Rectangular vessels: The design pressure is zero, and the design temperature range is determined according to the allowable use temperature of steel. Temperature determined. This section does not apply to the following containers: Containers that are directly heated by flames; Containers that are exposed to nuclear radiation; Containers that contain extremely or highly toxic media; Containers that are directly buried underground; Liftable gas cabinets; Containers that are frequently moved; Silo; Vertical cylindrical container with a geometric volume greater than 1000m; Tower container with a height greater than 10m and an aspect ratio greater than 5.