BS EN 61010-031:2002+A1:2008
Safety requirements for electrical equipment for measurement, control and laboratory use - Safety requirements for hand-held probe assemblies for electrical measurement and test

Standard No.
BS EN 61010-031:2002+A1:2008
Release Date
2002
Published By
British Standards Institution (BSI)
Status
 2015-08
Replace By
BS EN 61010-031:2015
Latest
BS EN 61010-031:2015+A1:2021
Replace
BS EN 61010-2-031:1995 98/230636 DC-1998 BS EN 61010-031:2002
Scope
This part of IEC 61010 applies to hand-held and hand-manipulated PROBE ASSEMBLIES of the types described below, and related accessories which are intended for professional, industrial process, and educational use. These PROBE ASSEMBLIES are for use in the interface between an electrical phenomenon and test or measurement equipment. They may be fixed to the equipment or be detachable accessories for the equipment. a) Low-voltage and high-voltage, non-attenuating PROBE ASSEMBLIES (type A). Non-attenuating PROBE ASSEMBLIES that are RATED for direct connection to voltages exceeding 33 V r.m.s. or 46,7 V peak or 70 V d.c., but not exceeding 63 kV. They do not incorporate active components, nor are they intended to provide a voltage divider function or a signal conditioning function, but they may contain passive non-attenuating components such as fuses. b) High-voltage attenuating or divider PROBE ASSEMBLIES (type B). Attenuating or divider PROBE ASSEMBLIES that are RATED for direct connection to secondary voltages exceeding 1 kV but not exceeding 63 kV. The divider function may be carried out wholly within the PROBE ASSEMBLY, or partly within the test or measurement equipment to be used with the PROBE ASSEMBLY. c) Low-voltage attenuating or divider PROBE ASSEMBLIES (type C). Attenuating, divider or other signal conditioning PROBE ASSEMBLIES for direct connection to voltages exceeding 33 V r.m.s or 46,7 V peak or 70 V d.c., but not exceeding 1 kV r.m.s. or 1,5 kV d.c. The signal conditioning function may be carried out wholly within the PROBE ASSEMBLY, or partly within the test or measurement equipment intended to be used with the PROBE ASSEMBLY. Low-voltage attenuating and non-attenuating PROBE ASSEMBLIES (type D), that are RATED for direct connection only to voltages not exceeding 33 V r.m.s., or 46,7 V peak, or 70 V d.c., and are suitable for currents exceeding 8 A.

BS EN 61010-031:2002+A1:2008 Referenced Document

  • IEC 60027 Letter Symbols to be used in electrical technology (Edition 4.0)
  • IEC 60060 High-voltage test techniques - ALL PARTS*2011-10-31 Update
  • IEC 60417 
  • IEC 60529 Degrees of Protection Provided by Enclosures (IP Code) (Edition 2.1 ***Applies to French text only***)*2024-04-19 Update
  • IEC 60664-3 Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution*2016-11-04 Update
  • ISO 7000 Graphical symbols for use on equipment — Index and synopsis*2019-07-12 Update

BS EN 61010-031:2002+A1:2008 history

  • 2022 BS EN 61010-031:2015+A1:2021 Safety requirements for electrical equipment for measurement, control and laboratory use - Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
  • 2015 BS EN 61010-031:2015 Safety requirements for electrical equipment for measurement, control and laboratory use. Safety requirements for hand-held probe assemblies for electrical measurement and test
  • 2002 BS EN 61010-031:2002+A1:2008 Safety requirements for electrical equipment for measurement, control and laboratory use - Safety requirements for hand-held probe assemblies for electrical measurement and test
  • 2002 BS EN 61010-031:2002 Safety requirements for electrical equipment for measurement, control and laboratory use - Safety requirements for hand-held probe assemblies for electrical measurement and test
  • 0000 BS EN 61010-2-031:1995
Safety requirements for electrical equipment for measurement, control and laboratory use - Safety requirements for hand-held probe assemblies for electrical measurement and test



Copyright ©2024 All Rights Reserved