IEC 60332-2-2:2004
Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame

Standard No.
IEC 60332-2-2:2004
Release Date
2004
Published By
International Electrotechnical Commission (IEC)
Latest
IEC 60332-2-2:2004
Replace
IEC 20/700/FDIS:2004 IEC 60332-2:1989
Scope
This part of GB/T 18380 specifies the method for vertical flame spread test of a single insulated thin wire, cable or thin optical cable under flame conditions. Test equipment is specified in GB/T 18380.21 2008. When the test method specified in GB/T 18380.12 2008 is not applicable, such as a thin optical cable that may break during the test fire supply or a thin wire whose conductor may fuse. This standard recommends testing thin optical cables with a total cross-section less than O. 5mm. Used when insulating thin wires and cables. Note: The use of insulated wire and cable complying with this standard is not sufficient to prevent the spread of flame under all laying conditions. In some highly dangerous situations, such as when bundled wires are laid vertically over a long length, one sample cannot be considered to meet the performance requirements of the vehicle standard, and the bundled wires will also show the same performance (see GB, T 18380 3l~36 series standards). See Appendix A for recommended performance requirements.

IEC 60332-2-2:2004 Referenced Document

  • GB/T 16499-1996 Guide to the drafting of electrical safety standards
  • GB/T 18380.21-2008 Tests on electric and optical fibre cables under fire conditions.Part 21:Test for vertical flame propagation for a single small insulated wire or cable.Apparatus*2008-06-26 Update
  • IEC 60695-4:1993 Fire hazard testing; part 4: terminology concerning fire test

IEC 60332-2-2:2004 history

  • 2004 IEC 60332-2-2:2004 Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame

IEC 60332-2-2:2004 Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame has been changed from IEC 60332-2:1989 Tests on electric cables under fire conditions; part 2: test on a single small vertical insulated copper wire or cable.

Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame