ASTM E1164-09a
Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation

Standard No.
ASTM E1164-09a
Release Date
2009
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM E1164-12
Latest
ASTM E1164-23
Scope

The most general and reliable methods for obtaining CIE tristimulus values or, through transformation of them, other coordinates for describing the colors of objects are by the use of spectrometric data. Colorimetric data are obtained by combining object spectral data with data representing a CIE standard observer and a CIE standard illuminant, as described in Practice E 308.

This practice provides procedures for selecting the operating parameters of spectrometers used for providing data of the desired precision. It also provides for instrument calibration by means of material standards, and for selection of suitable specimens for obtaining precision in the measurements.

1.1 This practice covers the instrumental measurement requirements, calibration procedures, and material standards needed to obtain precise spectral data for computing the colors of objects.

1.2 This practice lists the parameters that must be specified when spectrometric measurements are required in specific methods, practices, or specifications.

1.3 Most sections of this practice apply to both spectrometers, which can produce spectral data as output, and spectrocolorimeters, which are similar in principle but can produce only colorimetric data as output. Exceptions to this applicability are noted.

1.4 This practice is limited in scope to spectrometers and spectrometric colorimeters that employ only a single monochromator. This practice is general as to the materials to be characterized for color.

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6 This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM E1164-09a Referenced Document

  • ASTM D1003 Standard Test Method for Haze and Luminous Transmittance of Transparent Plastics
  • ASTM E1767 Standard Practice for Specifying the Geometry of Observations and Measurements to Characterize the Appearance of Materials
  • ASTM E179 Standard Guide for Selection of Geometric Conditions for Measurement of Reflection and Transmission Properties of Materials
  • ASTM E2153 Standard Practice for Obtaining Bispectral Photometric Data for Evaluation of Fluorescent Color
  • ASTM E2194 Standard Test Method for Multiangle Color Measurement of Metal Flake Pigmented Materials
  • ASTM E259 Standard Practice for Preparation of Pressed Powder White Reflectance Factor Transfer Standards for Hemispherical and Bi-Directional Geometries
  • ASTM E275 Standard Practice for Describing and Measuring Performance of Ultraviolet, Visible, and Near-Infrared Spectrophotometers
  • ASTM E284 Standard Terminology of Appearance
  • ASTM E308 Standard Practice for Computing the Colors of Objects by Using the CIE System
  • ASTM E387 Standard Test Method for Estimating Stray Radiant Power Ratio of Spectrophotometers by the Opaque Filter Method
  • ASTM E805 Standard Practice for Identification of Instrumental Methods of Color or Color-Difference Measurement of Materials
  • ASTM E925 Standard Practice for Monitoring the Calibration of Ultraviolet-Visible Spectrophotometers whose Spectral Slit Width does not Exceed 2 nm
  • ASTM E958 Standard Practice for Measuring Practical Spectral Bandwidth of Ultraviolet-Visible Spectrophotometers
  • ASTM E991 Standard Practice for Color Measurement of Fluorescent Specimens
  • ISO 2469 Paper, board and pulps

ASTM E1164-09a history

  • 2023 ASTM E1164-23 Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation
  • 2023 ASTM E1164-12(2023)e1 Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation
  • 2017 ASTM E1164-12(2017)e1 Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation
  • 2012 ASTM E1164-12e1 Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation
  • 2012 ASTM E1164-12 Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation
  • 2009 ASTM E1164-09a Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation
  • 2009 ASTM E1164-09 Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation
  • 2007 ASTM E1164-07 Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation
  • 2002 ASTM E1164-02 Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation
  • 1994 ASTM E1164-94 Standard Practice for Obtaining Spectrophotometric Data for Object-Color Evaluation
Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation



Copyright ©2024 All Rights Reserved