SANS 5201:2005
Water - Cadmium content

Standard No.
SANS 5201:2005
Release Date
2005
Published By
ZA-SANS
Status
 2010-03
Replace By
SANS 5201:2010
Latest
SANS 5201:2010
Scope
This standard specifies a method of determining the cadmium content of water and wastewater, using an air-acetylene flame and direct flame atomic absorption.The method is applicable to the determination of cadmium in the concentration range 0,05 mg/L to 2,0 mg/L, but the detection limit can be reduced to less than 0,01 mg/L by concentration of the sample through evaporation.When the sample has a high dissolved solid content, background correction may be required to eliminate non-specific or continuous absorption.

SANS 5201:2005 history