This part of IEC 61243 is applicable to portable voltage detectors@ with or without built-in power sources@ to be used on electrical systems for voltages of 1 kV to 765 kV a.c.@ and frequencies of 50 Hz and/or 60 Hz. This part applies only to voltage detectors of capacitive type used in contact with the part to be tested@ as a complete device including its insulating element or as a separate device@ adaptable to an insulating stick which@ as a separate tool@ is not covered by this standard (see 4.4.1 for general design). Other types of voltage detectors are not covered by this part of the standard. Some restrictions on their use are applicable in the case of factory-assembled switchgear and on overhead systems of electrified railways (see Annex B@ instructions for use). NOTE ?Except where otherwise specified@ all the voltages defined in this standard refer to values of phase-tophase voltages of three-phase systems. In other systems@ the applicable phase-to-phase or phase-to-earth (ground) voltages should be used to determine the operating voltage.
IEC 61243-1:2003/AMD1:2009 history
2021IEC 61243-1:2021 Live working - Voltage detectors - Part 1: Capacitive type to be used for voltages exceeding 1 kV AC
2009IEC 61243-1:2003/AMD1:2009 Live working - Voltage detectors - Part 1: Capacitive type to be used for voltages exceeding 1 kV a.c.
2009IEC 61243-1:2009 Live working - Voltage detectors - Part 1: Capacitive type to be used for voltages exceeding 1 kV a.c.
2005IEC 61243-1:2003/COR1:2005 Live working – Voltage detectors – Part 1: Capacitive type to be used for voltages exceeding 1 kV a.c. CORRIGENDUM 1 (Edition 2.0)
2005IEC 61243-1:2005 Live working - Voltage detectors - Part 1: Capacitive type to be used for voltages exceeding 1 kV a.c.
2003IEC 61243-1:2003 Live working - Voltage detectors - Part 1: Capacitive type to be used for voltages exceeding 1 kV a.c.
1970IEC 61243-1:1993/COR2:2000 Corrigendum 2 - Live working - Voltage detectors - Part 1: Capacitive type to be used for voltages exceeding 1 kV a.c.
2000IEC 61243-1/COR:2000 Live Working - Voltage Detectors - Part 1: Capacitive Type to Be Used for Voltages Exceeding 1 kV a.c. CORRIGENDUM (Edition 1.0; Amendment 1: 06-1997; Corrigendum: 07-1999)
1970IEC 61243-1:1993/COR1:1999 Corrigendum 1 - Live working - Voltage detectors - Part 1: Capacitive type to be used for voltages exceeding 1 kV a.c.
1970IEC 61243-1:1993/AMD1:1997 Amendment 1 - Live working - Voltage detectors - Part 1: Capacitive type to be used for voltages exceeding 1 kV a.c.
1993IEC 61243-1:1993 Live Working - Voltage Detectors - Part 1: Capacitive Type to Be Used for Voltages Exceeding 1 kV A.C. (Edition 1.0)