This part of GB/T 5023 specifies in detail the technical requirements for PVC insulated single-core unsheathed cables for fixed wiring with a rated voltage of 450/750 V and below. All cables shall comply with the corresponding requirements specified in GB/T 5023.1, and various types of cables shall comply with the special requirements specified in this section.
IEC 60227-3:1997 Referenced Document
GB/T 18380.12-2008 Test on electric and optical fibre cables under fire conditions.Part 12:Test for vertical flame propagation for a single insulated wire or cable.Procedure for 1kW pre-mixed flame*, 2008-06-26 Update
GB/T 2951.11-2008 Common test method for insulating and sheathing materials of electric and optical cables.Part 11:Methods for general application.Measurement of thickness and overall dimensions.Tests for determining the mechanical properties*, 2008-06-26 Update
GB/T 2951.12-2008 Common test methods for insulating and sheathing materials of electric and optical cables.Part 12:Methods for general application.Thermal ageing methods*, 2008-06-26 Update
GB/T 2951.14-2008 Common test methods for insulating and sheathing materials of electric and optical cables.Part 14:Methods for general application-Test at low temperature*, 2008-06-26 Update
GB/T 2951.31-2008 Common test methods for insulating and sheathing materials of electric and optical cables.Part31:Methods specific to PVC compounds.Pressure test at high temperature.Test for resistance to cracking*, 2008-06-26 Update
GB/T 2951.32-2008 Common test methods for insulating and sheathing materials of electric and optical cables.Part32:Methods specific to PVC compounds.Loss of mass test.Thermal stability test*, 2008-06-26 Update
GB/T 3956-1997 Conductors of insulated cables*, 1997-10-28 Update
GB/T 5023.1 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V.Part 1:General requirements*, 2008-06-30 Update
GB/T 5023.2-2008 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V.Part2:Test methods*, 2008-06-30 Update
IEC 60227-3:1997 history
0000 IEC 60227-3:2024 RLV
1997IEC 60227-3:1993/AMD1:1997 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 3: Non-sheathed cables for fixed wiring; Amendment 1
1997IEC 60227-3:1997 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V-Part3:Non-sheathed cables for fixed wiring
1993IEC 60227-3:1993 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V; part 3: non-sheathed cables for fixed wiring
1970IEC 60227-3:1973 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 3: Non-sheathed cables for fixed wiring