05/30131310 DC-200508/30194204 DC-200803/111132 DC-2003BS EN 60598-1:2004
Scope
This Part 1 of International Standard IEC 60598 specifies general requirements for luminaires,
incorporating electric light sources for operation from supply voltages up to 1 000 V. The
requirements and related tests of this standard cover: classification, marking, mechanical
construction and electrical construction.
Each section of this Part 1 is read in conjunction with this Section 0 and with other relevant
sections to which reference is made.
Each part of IEC 60598-2 details requirements for a particular type of luminaire or group of
luminaires on supply voltages not exceeding 1 000 V. These parts are published separately for
ease of revision and additional sections will be added as and when a need for them is
recognized.
Attention is drawn to the fact that this Part 1 covers all aspects of safety (electrical, thermal
and mechanical).
The presentation of photometric data for luminaires is under consideration by the International
Commission on Illumination (CIE) and is not, therefore, included in this Part 1.
Requirements are included in this Part 1 for luminaires incorporating ignitors with nominal peak
values of the voltage pulse not exceeding those of Table 11.2. The requirements apply to
luminaires with ignitors built into ballasts and to luminaires with ignitors separate from ballasts.
For luminaires with ignitors built into lamps, the requirements are under consideration.
Requirements for semi-luminaires are included in this Part 1.
In general, this Part 1 covers safety requirements for luminaires. The object of this Part 1 is to
provide a set of requirements and tests which are considered to be generally applicable to
most types of luminaires and which can be called up as required by the detail specifications of
IEC 60598-2. This Part 1 is thus not regarded as a specification in itself for any type of
luminaire, and its provisions apply only to particular types of luminaires to the extent
determined by the appropriate part of IEC 60598-2.
The parts of IEC 60598-2, in making reference to any of the sections of Part 1, specify the
extent to which that section is applicable and the order in which the tests are to be performed;
they also include additional requirements as necessary.
The order in which the sections of Part 1 are numbered has no particular significance as the
order in which their provisions apply is determined for each type of luminaire or group of
luminaires by the appropriate part of IEC 60598-2. All parts of IEC 60598-2 are self-contained
and therefore do not contain references to other parts of IEC 60598-2.
Where the requirements of any of the sections of Part 1 are referred to in the parts of
IEC 60598-2 by the phrase "The requirements of section... of IEC 60598-1 apply", this phrase
is to be interpreted as meaning that all the requirements of that section of Part 1 apply except
those which are clearly inapplicable to the particular type of luminaire covered by that part of
IEC 60598-2.
For explosion proof luminaires, as covered by IEC 60079, the requirements of IEC 60598
(selecting the appropriate parts 2) are applied in addition to the requirements of IEC 60079. In
the event of any conflict between IEC 60598 and IEC 60079, the requirements of IEC 60079
take priority.
IEC 60061-2 Lamp caps and holders together with gauges for the control of interchangeability and safety – Part 2: Lampholders
IEC 60079 Explosive atmospheres - ALL PARTS*, 2018-01-08 Update
IEC 60083 Plugs and Socket-Outlets for Domestic and Similar General Use Standards (Amendment 1-1979) (Edition 2.0)
IEC 60085 Electrical insulation - Thermal evaluation and designation
IEC 60155 Amendment 2 - Glow-starters for fluorescent lamps
IEC 60227 Corrigendum 1 - Polyvinyl chloride insulated flexible cables and cords with circular conductors and a rated voltage not exceeding 750 V
IEC 60245 Corrigendum 1 - Rubber insulated flexible cables and cords with circular conductors and a rated voltage not exceeding 750 V
IEC 60269 Low-voltage fuses - Part 7: Supplementary requirements for fuse-links for the protection of batteries and battery systems*, 2021-12-15 Update
IEC 60320 Amendment 3 - Appliance couplers for household and similar general purposes