Scope
This European Standard specifies the requirements, test methods and performance criteria for aspirating smoke detectors for use in fire detection and fire alarm systems installed in buildings. Aspirating smoke detectors developed for the protection of specific risks that incorporate special characteristics (including additional features or enhanced functionality for which this standard does not define a test or assessment method) are also covered by this standard. The performance requirements for any special characteristics are beyond the scope of this standard. NOTE Certain types of detector contain radioactive materials. The national requirements for radiation protection differ from country to country and they are not therefore specified in this standard.

DIN EN 54-20:2009 Referenced Document

  • EN 50130-4:1995 Alarm Systems Part 4: Electromagnetic Compatibility Product Family Standard: Immunity Requirements for Components of Fire@ Intruder and Social Alarm Systems
  • EN 54-1:1996 Fire Detection and Fire Alarm Systems - Part 1: Introduction Supersedes EN 54-1: 1976
  • EN 54-2 CORR Fire Detection and Fire Alarm Systems - Part 2: Control and Indicating Equipment Ratified European Text
  • EN 54-4 CORR Fire Detection and Fire Alarm Systems - Part 4: Power Supply Equipment Ratified European Text
  • EN 54-7:2000 Fire detection and fire alarm systems - Part 7: Smoke detectors - Point detectors using scattered light, transmitted light or ionization (Incorporates Amendments A1: 2002 and A2: 2006)*2024-04-19 Update
  • EN 60068-2-1 Environmental testing - Part 2-1: Tests - Test A: Cold
  • EN 60068-2-2 Environmental testing - Part 2-2: Tests - Test B: Dry heat
  • EN 60068-2-6 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
  • EN 61386-1:2004 Conduit systems for cable management Part 1: General requirements (Incorporating Corrigendum April 2004)

DIN EN 54-20:2009 history

  • 1970 DIN EN 54-20 E:2014-04 Fire detection and fire alarm systems - Part 20: Aspirating smoke detectors
  • 2014 DIN EN 54-20 E:2014 Draft Document - Fire detection and fire alarm systems - Part 20: Aspirating smoke detectors; German version prEN 54-20:2014
  • 2009 DIN EN 54-20:2009-02 Fire detection and fire alarm systems - Part 20: Aspirating smoke detectors; German version EN 54-20:2006+AC:2008 / Note: To be replaced by DIN EN 54-20 (2014-04).
  • 2009 DIN EN 54-20:2009 Fire detection and fire alarm systems - Part 20: Aspirating smoke detectors (includes Amendment AC:2008); English version of DIN EN 54-20:2009-02
  • 0000 DIN EN 54-20:2006
Fire detection and fire alarm systems - Part 20: Aspirating smoke detectors (includes Amendment AC:2008); English version of DIN EN 54-20:2009-02