- Standard No.
- IEC PAS 60539-1-1:2008
- Release Date
- 2008
- Published By
- International Electrotechnical Commission (IEC)
- Latest
-
IEC PAS 60539-1-1:2008
- Replace
-
IEC 40/1927/PAS:2008
- Scope
- 1.1 Method(s) of mounting (to be inserted)
(See 4.4 of IEC 60539-1:2008.)
1.2 Dimensions
(All dimensions are in millimetres or inches and millimetres; it shall be stated which
dimensions are suitable for gauging.)
Dimensioned drawing(s) shall be given in the detail specification. If necessary, the
dimensions may be listed in tabular form with reference to styles or codes.
1.3 Coating
The detail specification shall state:
a) whether the thermistor is insulated or non insulated;
b) the material;
c) the colour, if applicable.
1.4 Terminations
The detail specification shall state whether the terminations are suitable for soldering. If they are
not, suitable methods of connection shall be stated for example: welding, clamping or crimping.
1.5 Flammability
The detail specification shall state whether the thermistor is actively or passively flammable, if
applicable. The test method shall be given in the test schedule.
1.6 Resistance to solvents
The detail specification shall state whether the coating and the marking of the thermistor are
solvent resistant, if applicable. The test methods shall be given in the test schedule.
1.7 Packaging
The detail specification shall give the following information (if required):
a) whether bulk packed or taped and if taped, drawing or references;
b) the dimensions of the immediate packaging and the number of thermistors packed;
c) the dimensions of the outer package and the number of immediate packages;
d) methods of disposal of the packaging material.
IEC PAS 60539-1-1:2008 Referenced Document
- IEC 60539-1:2008 Directly heated negative temperature coefficient thermistors - Part 1: Generic specification
IEC PAS 60539-1-1:2008 history
- 2008 IEC PAS 60539-1-1:2008 Directly heated negative temperature coefficient thermistors - Part 1-1: Blank detail specification - Sensing application - Assessment level EZ
IEC PAS 60539-1-1:2008 Directly heated negative temperature coefficient thermistors - Part 1-1: Blank detail specification - Sensing application - Assessment level EZ has been changed from IEC 40/1927/PAS:2008 IEC/PAS 60539-1-1: Thermistors - Directly heated negative temperature coefficient - Part 1-1: Blank detail specification - Sensing application.