Scope
EN 50264-2-2 specifies requirements for, and constructions and dimensions of, multicore cables of the
following types and voltage ratings:
? 300/500 V screened or unscreened (1 mm?, 1,5 mm? and 2,5 mm?, number of cores from 2 to 40);
? 0,6/1 kV screened or unscreened (1,5 mm? to 50 mm?, 2, 3 and 4 cores).
NOTE Not all conductor sizes or number of cores are specified for every type.
All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free
sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is
encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a
maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s.
Under fire conditions the cables exhibit special performance characteristics in respect of maximum
permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases.
EN 50264-2-2 should be read in conjunction with Part 1 “General requirements”.
EN 50264-2-2:2008 history
2008EN 50264-2-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables