GB/T 16817-2008
Thermoluminescence dosimeter system for radiotherapy level monitoring (English Version)

Standard No.
GB/T 16817-2008
Language
Chinese, Available in English version
Release Date
2008
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Status
 2017-12
Latest
GB/T 16817-2008
Replace
GB/T 16817-1997
Scope
1.1 This standard specifies the performance requirements and detection methods of the thermoluminescence measurement system for radiotherapy level dose monitoring, as well as the dose measurement procedures involved in use. This standard is applicable to the measurement of the absorbed dose of X-radiation (bremsstrahlung), Coγ radiation and medical accelerator X-radiation (bremsstrahlung) generated under the condition of tube voltage 60kV~250kV. 1.2 This standard Thermoluminescent measuring system suitable for measuring absorbed dose under the following conditions: 1.2.1 Absorbed dose range: 0.5Gy~3.0Gy. 1.2.2 Absorbed dose rate range: 1×10-2Gy.min-1~10Gy.min-1. 1.2.3 Radiation type: a) X-bremsstrahlung radiation generated under the condition of tube voltage 60kV~250kV; b) Coγ radiation; c) X-bremsstrahlung radiation generated by accelerator with nominal voltage 0.6MV~50MV. 1.2.4 Temperature range: 15℃~25℃. 1.2.5 Humidity range: 50%RH~75%RH. 1.2.6 Atmospheric pressure range: 86.0kPa~106.6kPa. 1.3 This standard does not address use-related safety issues, if any. The user of this standard is responsible for establishing applicable safety and health standards and determining applicable limitations prior to use.

GB/T 16817-2008 Referenced Document

  • GB/T 17857 Medical radiology--Terminology(Equipment for radiotherapy,nuclear medicine and radiation dosimetry)
  • IEC 61066 Thermoluminescence dosimetry systems for personal and environmental monitoring
  • ISO/ASTM 51956 Practice for use of a thermoluminescence-dosimetry system (TLD system) for radiation processing*2013-11-15 Update
  • JJG 589 Verification Regulationof Medical Electron Accelerator Radiation Source*2008-12-22 Update
  • JJG 912 Verification Regulation of Ionization Chamber Dosimeters Used in Radiotherapy *2010-06-10 Update

GB/T 16817-2008 history

  • 2008 GB/T 16817-2008 Thermoluminescence dosimeter system for radiotherapy level monitoring
  • 1997 GB/T 16817-1997 Thermoluminescence dosimeter system for radiotherapy level monitoring
Thermoluminescence dosimeter system for radiotherapy level monitoring