BS EN 60898-1:2003+A1:2004
Electrical accessories - Circuit breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation

Standard No.
BS EN 60898-1:2003+A1:2004
Release Date
2003
Published By
British Standards Institution (BSI)
Status
 2003-09
Replace By
BS EN 60898-1:2003+A13:2012
Latest
BS EN 60898-1:2019
Replace
93/215621 DC-1993 94/202552 DC-1994 97/207511 DC-1997 97/208713 DC-1997 92/05857 DC-1992 95/205461 DC-1995 95/213086 DC-1995 BS EN 60898-1:2003 96/211300 DC-1996 99/201694 DC-1999 BS EN 60898:1991
Scope
This part of IEC 60898 applies to a.c. air-break circuit-breakers for operation at 50 Hz or 60 Hz, having a rated voltage not exceeding 440 V (between phases), a rated current not exceeding 125 A and a rated short-circuit capacity not exceeding 25 000 A. As far as possible, it is in line with the requirements contained in IEC 60947-2. These circuit-breakers are intended for the protection against overcurrents of wiring installations of buildings and similar applications; they are designed for use by uninstructed people and for not being maintained. They are intended for use in an environment with pollution degree 2 They are suitable for isolation. Circuit-breakers of this standard are suitable for use in IT systems provided that the requirements of HD 384.4.473 are complied with. This standard also applies to circuit-breakers having more than one rated current, provided that the means for changing from one discrete rating to another is not accessible in normal service and that the rating cannot be changed without the use of a tool. This standard does not apply to – circuit-breakers intended to protect motors; – circuit-breakers, the current setting of which is adjustable by means accessible to the user. For circuit-breakers having a degree of protection higher than IP20 according to EN 60529, for use in locations where arduous environmental conditions prevail (e.g. excessive humidity, heat or cold or deposition of dust) and in hazardous locations (e.g. where explosions are liable to occur), special constructions may be required. Requirements for circuit-breakers for a.c. and d.c. operation are given in EN 60898-2. Requirements for circuit-breakers which incorporate residual current tripping devices are to be found in EN 61009-1 and EN 61009-2-1. Supplementary requirements may be necessary for circuit-breakers of the screw-in types.  A guide for co-ordination under short-circuit conditions between a circuit-breaker and another short-circuit protective device (SCPDs) is given in annex D.NOTE 2 For an environment with a higher pollution degree, enclosures giving the appropriate degree of protection should be used. NOTE 3 Circuit-breakers within the scope of this standard may also be used for protection against electric shock in case of fault, depending on their tripping characteristics and on the characteristics of the installation. The criterion of application for such purposes is dealt with by installation rules. NOTE 4 Recommendations for the dimensional coordination between enclosures and circuit breakers for mounting on rail according to EN 60715 or equivalent means are given in the CENELEC report R023-001. This standard contains all requirements necessary to ensure compliance with the operational characteristics required for these devices by type tests.

BS EN 60898-1:2003+A1:2004 Referenced Document

  • IEC 60112 Method for the determination of the proof and the comparative tracking indices of solid insulating materials*2020-10-28 Update
  • IEC 60227 Corrigendum 1 - Polyvinyl chloride insulated flexible cables and cords with circular conductors and a rated voltage not exceeding 750 V
  • IEC 60269 Low-voltage fuses - Part 7: Supplementary requirements for fuse-links for the protection of batteries and battery systems*2021-12-15 Update
  • IEC 60364 Low-voltage electrical installations - Part 8-82: Functional aspects - Prosumer's low-voltage electrical installations*2022-10-20 Update
  • IEC 60417 
  • IEC 60529 Degrees of Protection Provided by Enclosures (IP Code) (Edition 2.1 ***Applies to French text only***)*2024-04-19 Update
  • IEC 60664-1 IEC 60664-1-cor1{ed3.0}b*2024-04-19 Update

BS EN 60898-1:2003+A1:2004 history

  • 1970 BS EN 60898-1:2019 Electrical accessories. Circuit-breakers for overcurrent protection for household and similar installations. Circuit-breakers for a.c. operation
  • 2003 BS EN 60898-1:2003+A13:2012 Electrical accessories ˝ Circuit breakers for overcurrent protection for household and similar installations. Circuit-breakers for a.c. operation
  • 2003 BS EN 60898-1:2003+A1:2004 Electrical accessories - Circuit breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation
  • 2003 BS EN 60898-1:2003 Electrical accessories - Circuit-beakers for overcurrent protection for household and similar installations - Circuit breakers for a.c. operation



Copyright ©2024 All Rights Reserved