1.1 This standard applies to 60 – 250°C single- or multiple-conductor jacketed or unjacketed, integral or nonintegral cables and single or multiple coaxial cables for telephone and other communication circuits such as voice, data, and audio for on-premise customer systems. These cables are not prohibited from containing one or more optical fibre members. For the purpose of this standard, a coaxial cable or coaxial member conductor is a single conductor with a shield. For the purpose of this standard, a single- or multiple-conductor unjacketed cable is a cross-connect wire.
1.2 This standard applies to communications cables that are intended primarily for installation in
accordance with Section 60 of the Canadian Electrical Code (CEC), Part I, and Article 800 of the National Electrical Code (NEC), ANSI/NFPA 70. They are rated for 300 V applications but are not so marked.
1.3 This standard does not apply to communications cords.
1.4 In Canada, Type CMUC, cross-connect communications cables, and the "-CI" circuit integrity markings are not recognized by the Canadian Electrical Code, Part I.
In the US, Type CMH is not recognized in the NEC.
1.5 If a value for measurement is followed by a value in other units in parenthesis, the second value may be only approximate. The first stated value is the requirement.
UL 444-2008 Referenced Document
ASTM B189 Standard Specification for Lead-Coated and Lead-Alloy-Coated Soft Copper Wire for Electrical Purposes
ASTM B298 Standard Specification for Silver-Coated Soft or Annealed Copper Wire
ASTM B33 Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes
ASTM B355 Standard Specification for Nickel-Coated Soft or Annealed Copper Wire
ASTM B869 Standard Specification for Copper-Clad Steel Electrical Conductor for CATV Drop Wire
ASTM D5374 Standard Test Methods for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation
ASTM D5423 Standard Specification for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation
2018UL 444 CRD-2018 UL Standard for Safety Communications Cables - Section / Paragraph Reference: Subject: Use of an Additional 14 AWG Conductor in a Multi-conductor Communications Cable (Edition 5: January 20@ 2017)
2018UL 444 BULLETIN-2018 UL Standard for Safety Communications Cables (COMMENTS DUE: April 23@ 2018)
2017UL 444 BULLETIN-2017 UL Standard for Safety Communications Cables (COMMENTS DUE: November 20@ 2017)
2017UL 444-2017 UL Standard for Safety Communications Cables (Fifth Edition)
2015UL 444 CRD-2015 UL Standard for Safety Communications Cables Section / Paragraph Reference: 7.24 (New)@ 8.4.6 (New) Subject: New – LP ratings (Edition 4: July 11@ 2008)
2015UL 444 BULLETIN-2015 UL Standard for Safety Communications Cables (COMMENTS DUE: November 23@ 2015)
2014UL 444 BULLETIN-2014 UL Standard for Safety Communications Cables (COMMENTS DUE: October 27@ 2014)
2012UL 444 CRD-2012 UL Standard for Safety Communications Cables - Section / Paragraph Reference: Pars. 5.1.1, 5.1.3, 7.17 Tables 1, 2, 3, and 5 Subject: Coaxial Cables - Copper Tube Center Conductor (Edition 4: July 11, 2008)