- Standard No.
- GB/T 8177-2004
- Language
- Chinese, Available in English version
- Release Date
- 2004
- Published By
- General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
- Latest
-
GB/T 8177-2004
- Replace
-
GB/T 9057-1988
GB/T 8177-1987
- Scope
- This standard specifies the terms and definitions, types and basic parameters, requirements, inspection methods, marking and packaging of two-point inner micrometers (including "inner micrometer" and "single-rod inner micrometer"). This standard is applicable to the overall structure with a division value of 0.01mm, 0.001mm, 0.002mm, 0.005mm, the pitch of the micrometer screw is 0.5mm or 1.0mm, and the measurement upper limit ιmax should not be greater than 6000mm or with Two-point inside micrometer for extension rods (according to Abbe's principle).
GB/T 8177-2004 history
GB/T 8177-2004 Internal micrometers with two-point contact has been changed from GB/T 9057-1988 Single-body inside micrometers.