BS 5467:1997+A3:2008
Electric cables - Thermosetting insulated, armoured cables for voltages of 600/1000 V and 1900/3300 V

Standard No.
BS 5467:1997+A3:2008
Release Date
1997
Published By
British Standards Institution (BSI)
Status
 2016-04
Replace By
BS 5467:2016
Latest
BS 5467:2016
Replace
BS 5467:1989 BS 5467:1997+A2:2005
Scope
This British Standard specifies requirements for construction and describes methods of test for armoured cable with thermosetting insulation of rated voltages 600/1 000 V and 1 900/3 300 V. Cables specified in this standard are intended for use in fixed installations in industrial areas, buildings and similar applications. The insulation and other components are suitable to permit operation of the cables at a maximum sustained conductor temperature of 90 °C and for a maximum short-circuit conductor temperature of 250 °C. NOTE 1 Limitation on the temperature of the cables may be imposed in situations where they may be touched. NOTE 2 Due to the relatively high conductor temperature, there is a risk of drying out the surrounding soil, causing an increase in thermal resistivity, which in turn would lead to the cable temperature rising to a higher value than anticipated. For cable laid directly in the ground, a suitable de-rating factor should be applied or a lower maximum sustained conductor operating temperature assumed to take into account the possible effects of soil drying out. NOTE 3 In installations which include cable joints and terminations, the performance of these accessories should be taken into account in deciding the maximum operating temperature of the cable. Cables specified in this standard are: single-core stranded copper conductor; single-core solid aluminium conductor; two-, three-, four- and five-core stranded copper conductor; two-, three-, and four-core solid aluminium conductor; multicore auxiliary stranded copper conductor. b) 1 900/3 300 V cables, wire armoured and oversheathed, having: single-core stranded copper conductor; single-core solid aluminium conductor; three-core stranded copper conductor; three-core solid aluminium conductor. Annex A gives recommendations for the selection and operation of cables while recommendations for the installation of cables are given in Annex B. Annex C lists the information that should be given with an enquiry or order.

BS 5467:1997+A3:2008 Referenced Document

  • BS EN 10244-2 Steel wire and wire products — Non - ferrous metallic coatings on steel wire Part 2 : Zinc or zinc alloy coatings
  • BS EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions-Test for vertical flame propagation for a single insulated wire or cable. Procedure for 1 kW pre-mixed flame*2015-11-30 Update

BS 5467:1997+A3:2008 history

  • 2016 BS 5467:2016 Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations. Specification
  • 1997 BS 5467:1997+A3:2008 Electric cables - Thermosetting insulated, armoured cables for voltages of 600/1000 V and 1900/3300 V
  • 1997 BS 5467:1997 Electric cables - Thermosetting insulated, armoured cables for voltages of 600/1000 V and 1900/3300 V
  • 0000 BS 5467:1989
Electric cables - Thermosetting insulated, armoured cables for voltages of 600/1000 V and 1900/3300 V