1.1 These test methods cover the chemical analysis of stainless, heat-resisting, maraging, and other similar chromium-nickel-iron alloys having chemical compositions within the following limits:
Element | Concentration Range, % | |
Aluminum | 0.002 | to 5.50 |
Boron | 0.001 | to 0.20 |
Carbon | 0.01 | to 1.50 |
Chromium | 0.01 | to 35.00 |
Cobalt | 0.01 | to 15.00 |
Columbium (Niobium) | 0.01 | to 4.00 |
Copper | 0.01 | to 5.00 |
Lead | 0.001 | to 0.50 |
Manganese | 0.01 | to 20.00 |
Molybdenum | 0.01 | to 7.00 |
Nickel | 0.01 | to 48.00 |
Nitrogen | 0.001 | to 0.50 |
Phosphorus | 0.002 | to 0.35 |
Selenium | 0.01 | to 0.50 |
Silicon | 0.01 | to 4.00 |
Sulfur | 0.002 | to 0.50 |
Tantalum | 0.01 | to 0.80 |
Tin | 0.001 | to 0.05 |
Titanium | 0.01 | to 4.50 |
Tungsten | 0.01 | to 4.50 |
Vanadium | 0.005 | to 1.00 |
Zirconium | 0.001 | to 0.20 |
1.2 The test methods in this standard are contained in the sections indicated below:
Sections | |
Aluminum, Total, by the 8-Quinolinol Gravimetric Method (0.20 to 7.00 %) | 119 |
Aluminum, Total, by the 8-Quinolinol Photometric Method (0.003 to 0.20 %) | 71 |
Carbon, Total, by the Combustion-Thermal Conductivity Method | 2a |
Carbon, Total, by the Combustion Gravimetric Method (0.05 to 1.50 %) | 98 |
Chromium by the Atomic Absorption Method (0.006 to 1.00 %) | 202 |
Chromium by the Peroxydisulfate Oxidation-Titration Method (0.10 to 35.00 %) | 212 |
Chromium by the Peroxydisulfate-Oxidation Titrimetric Method | 2b |
Cobalt by the Ion-Exchange-Potentiometric Titration Method (2 to 15. %) | 53 |
Cobalt by the Nitroso-R-Salt Photometric Method (0.01 to 5.0 %) | 61 |
Copper by the Neocuproine Photometric Method (0.01 to 5.00) %) | 109 |
Copper by the Sulfide Precipitation-Electrodeposition Gravimetric Method (0.01 to 5.00 %) | 82 |
Lead by the Ion-Exchange-Atomic Absorption Method (0.001 to 0.50 %) | 127 |
Manganese by the Periodate Photometric Method (0.01 to 5.00 %) | 8 |
Molybdenum by the Ion Exchange-8-Hydroxyquinoline Gravimetric Method | 242 |
Molybdenum by the Photometric Method (0.01 to 1.50 %) | 190 |
Nickel by the Dimethylglyoxime Gravimetric Method (0.1 to 48.0 %) | 172 |
Phosphorus by the Alkalimetric Method (0.02 to 0.35 %) | 164 |
Phosphorus by the Molybdenum Blue Photometric Method (0.002 to 0.35 %) | 18 |
Silicon by the Gravimetric Method (0.05 to 4.00 %) | 46 |
Sulfur by the Gravimetric Method | 2c |
Sulfur by the Combustion-Iodate Titration Method (0.005 to 0.5 %) | 37 |
Sulfur by the Chromatographic Gravimetric Method | 2b |
Tin by the Solvent Extraction-Atomic Absorption Method (0.002 to 0.10 %) | 180 |
Tin by the Sulfide-Iodometric Titration Method (0.01 to 0.05 %) | 90 |
Titanium, Total, by the Dia......