ASTM E367-02
Standard Methods for Chemical Analysis of Ferrocolumbium

Standard No.
ASTM E367-02
Release Date
2002
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM E367-03
Latest
ASTM E367-22
Scope

1.1 These methods cover the chemical analysis of ferrocolumbium having chemical compositions within the following limits:

ElementConcentration, %
Aluminum2.00 max
Carbon0.30 max
Chromium2.00 max
Cobalt0.25 max
Niobium40.00 to 75.00
Lead0.01 max
Manganese3.00 max
Phosphorus0.05 max
Silicon4.00 max
Sulfur0.03 max
Tantalum7.00 max
Tin0.15 max
Titanium5.00 max
Tungsten0.50 max

1.2 The methods appear in the following order:

Sections
Niobium, Tantalum, and Titanium by the
Ion-Exchange Method9-30

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of whoever uses this standard to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 5.

ASTM E367-02 history

  • 2022 ASTM E367-22 Standard Test Methods for Chemical Analysis of Ferroniobium
  • 2016 ASTM E367-16 Standard Test Methods for Chemical Analysis of Ferroniobium
  • 2009 ASTM E367-09 Standard Test Methods for Chemical Analysis of Ferroniobium
  • 2003 ASTM E367-03 Standard Methods for Chemical Analysis of Ferroniobium
  • 2002 ASTM E367-02 Standard Methods for Chemical Analysis of Ferrocolumbium
  • 1983 ASTM E367-83(1997)e1 Standard Methods for Chemical Analysis of Ferrocolumbium



Copyright ©2024 All Rights Reserved