ASTM E1873-06
Standard Guide for Detection of Nucleic Acid Sequences by the Polymerase Chain Reaction Technique

Standard No.
ASTM E1873-06
Release Date
2006
Published By
American Society for Testing and Materials (ASTM)
Status
 2014-08
Latest
ASTM E1873-06
Scope

This guide is intended for use in any laboratory utilizing PCR or RT-PCR to amplify and detect a specific nucleic acid sequence.

The criteria used for evaluation of the amplification reactions should be administered by an individual trained in the use of molecular biological techniques associated with PCR.

1.1 This guide covers guidelines, recommendations, basic considerations, criteria, and principles to be employed when developing, utilizing, or assessing PCR procedures and specific protocols for the amplification and detection of nucleic acid sequences. This guide is not intended to be a standard procedure with a list of requirements for PCR detection of nucleic acids. This guide is intended to provide information that will assist the user in obtaining quality and reliable data.

1.2 Nucleic acid targets for PCR include DNA, as well as RNA ; RNA sequences are suitable targets for PCR following reverse transcription of the RNA to complementary DNA (cDNA). This type of amplification technique is known as reverse transcription-PCR (RT-PCR).

1.3 This guide has been developed for use in any molecular biology/biotechnology laboratory. This includes, but is not limited to, laboratories that specialize in the diagnosis of human, animal, plant, or bacterial diseases.

1.4 This guide conveys the general procedural terminology of PCR technology used for the detection of nucleic acids.

1.5 This guide is general; it does not cover the additional guidance that would be needed for specific applications, for example, for the PCR detection of nucleic acid sequences of specific microorganisms.

1.6 This guide does not cover details of the various methods that can be utilized to identify PCR-amplified DNA sequences.

1.7 This guide does not cover specific variations of the basic PCR or RT-PCR technology (for example, quantitative PCR, real-time PCR, multiplex PCR, and in situ PCR), and it does not cover details of instrument calibration.

1.8 Warning-Laboratory work involving certain clinical specimens and microorganisms can be hazardous to personnel. Warning-Biosafety level 2 (or higher) facilities are recommended for biohazard work (). Safety guidelines should be adhered to in accordance with CLSI M29-A2 and other recommendations ().

ASTM E1873-06 history

  • 2006 ASTM E1873-06 Standard Guide for Detection of Nucleic Acid Sequences by the Polymerase Chain Reaction Technique
  • 2004 ASTM E1873-04 Standard Guide for Detection of Nucleic Acid Sequences by the Polymerase Chain Reaction Technique
  • 1997 ASTM E1873-97(2002) Standard Guide for Detection of Nucleic Acid Sequences by the Polymerase Chain Reaction Technique
  • 1997 ASTM E1873-97 Standard Guide for Detection of Nucleic Acid Sequences by the Polymerase Chain Reaction Technique
Standard Guide for Detection of Nucleic Acid Sequences by the Polymerase Chain Reaction Technique



Copyright ©2024 All Rights Reserved