ASTM D6800-02(2007)e1
Standard Practice for Preparation of Water Samples Using Reductive Precipitation Preconcentration Technique for ICP-MS Analysis of Trace Metals

Standard No.
ASTM D6800-02(2007)e1
Release Date
2002
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM D6800-12
Latest
ASTM D6800-18
Scope

Ambient marine waters generally contain very low concentrations of toxic metals that require sensitive analytical methods, such as ICP-MS, to detect and measure the metalrsquo;concentrations.

Due to the high dissolved salt concentrations present in seawater, sample pretreatment is required to remove signal suppression and significant polyatomic interferences due to the matrix both of which compromise detection limits.

1.1 Toxic elements may be present in ambient waters and may enter the food chain via uptake by plants and animals; the actual concentrations of toxic metals are usually sub-ng/mL. The U.S. EPA has published its Water Quality Standards in the U.S. Federal Register 40 CFR 131.36, Minimum requirements for water quality standards submission, Ch. I (7-1-00 Edition), see Annex, . The U.S. EPA has also developed Method 1640 to meet these requirements, see Annex, .

1.2 Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) is a technique with sufficient sensitivity to routinely measure toxic elements in ambient waters, both fresh and saline (Test Method D 5673). However saline and hard water matrices pose analytical challenges for direct multielement analysis by ICP-MS at the required sub-ng/mL levels.

1.3 This standard practice describes a method used to prepare water samples for subsequent multielement analysis using ICP-MS. The practice is applicable to seawater and fresh water matrices, which may be filtered or digested. Samples prepared by this method have been analyzed by ICP-MS for the elements listed in Annex, Table A1.3).

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM D6800-02(2007)e1 Referenced Document

  • ASTM D1129 Standard Terminology Relating to Water
  • ASTM D1193 Standard Specification for Reagent Water
  • ASTM D5673 Standard Test Method for Elements in Water by Inductively Coupled Plasma8212;Mass Spectrometry
  • ASTM D5810 Standard Guide for Spiking into Aqueous Samples 
  • ASTM D5847 Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis

ASTM D6800-02(2007)e1 history

  • 2018 ASTM D6800-18 Standard Practice for Preparation of Water Samples Using Reductive Precipitation Preconcentration Technique for ICP-MS Analysis of Trace Metals
  • 2012 ASTM D6800-12 Standard Practice for Preparation of Water Samples Using Reductive Precipitation Preconcentration Technique for ICP-MS Analysis of Trace Metals
  • 2002 ASTM D6800-02(2007)e1 Standard Practice for Preparation of Water Samples Using Reductive Precipitation Preconcentration Technique for ICP-MS Analysis of Trace Metals
  • 2002 ASTM D6800-02 Standard Practice for Preparation of Water Samples Using Reductive Precipitation Preconcentration Technique for ICP-MS Analysis of Trace Metals
Standard Practice for Preparation of Water Samples Using Reductive Precipitation Preconcentration Technique for ICP-MS Analysis of Trace Metals



Copyright ©2024 All Rights Reserved