Scope

1.1 This guide recommends the criteria to be considered in specifying removable insulation covers for surfaces operating in air at temperatures above ambient.

1.2 A removable insulation cover is fabricated from a fibrous insulation material encased in a tailored fabric or wire mesh enclosure, or both. The fabric seams are typically held together with thread, metal rings, or staples, or combination thereof. These covers must be designed and fabricated to allow a close fit with tight joints over piping, elbows, flanges, valves, and tanks. They are intended to be easily removed and replaced to allow for periodic access to the surfaces they cover.

1.3 In addition to thermal performance, there are other performance requirements of removable covers. These may include, but are not limited to:

1.3.1 Temperature exposure,

1.3.2 Chemical and weather exposure,

1.3.3 Acoustical, and

1.3.4 Fire endurance.

1.4 The materials from which the cover is made may include, but are not limited to:

1.4.1 Insulation media,

1.4.2 Fabric, metal mesh enclosure, or foil enclosure,

1.4.3 Seam materials (thread, metal hooks, etc.), and

1.4.4 Attachment system (hook and loop attachment, straps, wire, etc.).

1.5 The shape, size, and physical design of the cover varies depending on the object to be covered. The cover may consist of more than one piece. Pipes, valves, pumps, and flanges are typical objects to be covered. In many cases, on-site measurements need to be made to ensure an acceptable fit.

1.6 The values stated in SI units shall be regarded as the standard. The values given in parentheses are provided for information only.

1.7 This guide does not intend to establish the criteria required in the design of the equipment over which removable insulation covers are used, nor does this guide establish or recommend the applicability of removable insulation covers over all surfaces.

1.8 It is the responsibility of the user, user''s agent, or both, to determine applicability of this guide to their specific application and to inform the equipment designer of the intent to insulate so that appropriate design criteria can be established.

1.9 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use

1.10 This standard should be used to measure and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products, or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use

ASTM C1094-01(2006) Referenced Document

  • ASTM C1393 Standard Specification for Perpendicularly Oriented Mineral Fiber Roll and Sheet Thermal Insulation for Pipes and Tanks
  • ASTM C165 Standard Test Method for Measuring Compressive Properties of Thermal Insulations
  • ASTM C167 Standard Test Methods for Thickness and Density of Blanket or Batt Thermal Insulations
  • ASTM C1682 Standard Guide for Characterization of Spent Nuclear Fuel in Support of Interim Storage, Transportation and Geologic Repository Disposal
  • ASTM C177 Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus
  • ASTM C335 Standard Test Method for Steady-State Heat Transfer Properties of Horizontal Pipe Insulation
  • ASTM C411 Standard Test Method for Hot-Surface Performance of High-Temperature Thermal Insulation
  • ASTM C423 Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method
  • ASTM C547 Standard Specification for Mineral Fiber Preformed Pipe Insulation
  • ASTM C553 Standard Specification for Mineral Fiber Blanket And Felt Insulation (Industrial Type)
  • ASTM C592 Standard Specification for Mineral Fiber Blanket Insulation and Blanket-Type Pipe Insulation (Metal-Mesh Covered) (Industrial Type)
  • ASTM C795 Standard Specification for Thermal Insulation for Use in Contact with Austenitic Stainless Steel
  • ASTM C892 Standard Specification for High-Temperature Fiber Blanket Thermal Insulation
  • ASTM D1117 Standard Guide for Evaluating Nonwoven Fabrics
  • ASTM D1683 Standard Test Method for Failure in Sewn Seams of Woven Apparel Fabrics*2024-04-19 Update
  • ASTM D1894 Standard Test Method for Static and Kinetic Coefficients of Friction of Plastic Film and Sheeting*2024-04-19 Update
  • ASTM D2176 Standard Test Method for Folding Endurance of Paper by the M.I.T. Tester
  • ASTM D4157 Standard Test Method for Abrasion Resistance of Textile Fabrics (Oscillatory Cylinder Method)
  • ASTM D471 Standard Test Method for Rubber Property-Effect of Liquids
  • ASTM D751 Standard Test Methods for Coated Fabrics
  • ASTM E119 Standard Test Methods for Fire Tests of Building Construction and Materials
  • ASTM E596 Standard Test Method for Laboratory Measurement of Noise Reduction of Sound-Isolating Enclosures
  • ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials
  • ASTM G26 Practice for Operating Light-Exposure Apparatus (Xenon-Arc Type) With and Without Water for Exposure of Nonmetallic Materials (Withdrawn 2000)

ASTM C1094-01(2006) history

Standard Guide for Flexible Removable Insulation Covers



Copyright ©2024 All Rights Reserved