ASTM E1855-05e1
Standard Test Method for Use of 2N2222A Silicon Bipolar Transistors as Neutron Spectrum Sensors and Displacement Damage Monitors

Standard No.
ASTM E1855-05e1
Release Date
2005
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM E1855-10
Latest
ASTM E1855-20
Scope

1.1 This test method covers the use of 2N2222A silicon bipolar transistors as dosimetry sensors in the determination of neutron energy spectra, and as silicon 1-MeV equivalent displacement damage fluence monitors.

1.2 The neutron displacement damage is especially valuable as a spectrum sensor in the range 0.1 to 2.0 MeV when fission foils are not available. It has been applied in the fluence range between 2 X 1012 n/cm2 and 1 X 1014 n/cm2 and should be useful up to 1015 n/cm2. This test method details the steps for the acquisition and use of silicon 1-MeV equivalent fluence information (in a manner similar to the use of activation foil data) for the determination of neutron spectra.

1.3 In addition, this sensor can provide important confirmation of neutron spectra determined with other sensors, and yields a direct measurement of the silicon 1-MeV fluence by the transfer technique.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

ASTM E1855-05e1 Referenced Document

  • ASTM E170 Standard Terminology Relating to Radiation Measurements and Dosimetry
  • ASTM E1854 Standard Practice for Ensuring Test Consistency in Neutron-Induced Displacement Damage of Electronic Parts
  • ASTM E2005 Standard Guide for Benchmark Testing of Reactor Dosimetry in Standard and Reference Neutron Fields
  • ASTM E261 Standard Practice for Determining Neutron Fluence, Fluence Rate, and Spectra by Radioactivation Techniques
  • ASTM E265 Standard Test Method for Measuring Reaction Rates and Fast-Neutron Fluences by Radioactivation of Sulfur-32
  • ASTM E720 Standard Guide for Selection and Use of Neutron-Activation Foils for Determining Neutron Spectra Employed in Radiation-Hardness Testing of Electronics
  • ASTM E721 Standard Guide for Determining Neutron Energy Spectra from Neutron Sensors for Radiation-Hardness Testing of Electronics
  • ASTM E722 Standard Practice for Characterizing Neutron Energy Fluence Spectra in Terms of an Equivalent Monoenergetic Neutron Fluence for Radiation-Hardness Testing of Electronics
  • ASTM E844 Standard Guide for Sensor Set Design and Irradiation for Reactor Surveillance, E 706(IIC)
  • ASTM E944 Standard Guide for Application of Neutron Spectrum Adjustment Methods in Reactor Surveillance, (IIA)

ASTM E1855-05e1 history

  • 2020 ASTM E1855-20 Standard Test Method for Use of 2N2222A Silicon Bipolar Transistors as Neutron Spectrum Sensors and Displacement Damage Monitors
  • 2015 ASTM E1855-15 Standard Test Method for Use of 2N2222A Silicon Bipolar Transistors as Neutron Spectrum Sensors and Displacement Damage Monitors
  • 2010 ASTM E1855-10 Standard Test Method for Use of 2N2222A Silicon Bipolar Transistors as Neutron Spectrum Sensors and Displacement Damage Monitors
  • 2005 ASTM E1855-05e1 Standard Test Method for Use of 2N2222A Silicon Bipolar Transistors as Neutron Spectrum Sensors and Displacement Damage Monitors
  • 2005 ASTM E1855-05 Standard Test Method for Use of 2N2222A Silicon Bipolar Transistors as Neutron Spectrum Sensors and Displacement Damage Monitors
  • 2004 ASTM E1855-04e1 Standard Test Method for Use of 2N2222A Silicon Bipolar Transistors as Neutron Spectrum Sensors and Displacement Damage Monitors
  • 2004 ASTM E1855-04 Standard Test Method for Use of 2N2222A Silicon Bipolar Transistors as Neutron Spectrum Sensors and Displacement Damage Monitors
  • 1996 ASTM E1855-96 Standard Test Method for Use of 2N2222A Silicon Bipolar Transistors as Neutron Spectrum Sensors and Displacement Damage Monitors
Standard Test Method for Use of 2N2222A Silicon Bipolar Transistors as Neutron Spectrum Sensors and Displacement Damage Monitors