ASTM D5007-99(2003)
Standard Test Method for Wet-to-Dry Hiding Change

Standard No.
ASTM D5007-99(2003)
Release Date
1999
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM D5007-99(2008)
Latest
ASTM D5007-99(2017)
Scope

Many architectural paints, particularly white and light tints, change significantly in film opacity as they dry. An increase in hiding is sometimes associated with porosity and poor film integrity with conventionally formulated coatings. A decrease can result in a disappointing paint job. The wet-to-dry hiding change is therefore a property of great practical importance.

This test method can be used in paint specifications and as a short, simple procedure for evaluation and quality control.

1.1 This test method covers the determination of the change in hiding power of an architectural coating during drying, by visual evaluation of the wet and dry film.

1.2 This test method is not recommended for colors other than white and tints.

1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.