BS EN 60079-29-2:2007
Explosive atmospheres - Part 29-2: Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen

Standard No.
BS EN 60079-29-2:2007
Release Date
2008
Published By
British Standards Institution (BSI)
Status
 2015-05
Replace By
BS EN 60079-29-2:2015
BS EN 60079-29-2:2008
Latest
BS EN 60079-29-2:2015
Replace
04/30112683 DC-2004 BS EN 50073:1999
Scope
This part of IEC 60079-29 gives guidance on, and recommended practice for, the selection, installation, safe use and maintenance of electrically operated group II apparatus intended for use in industrial and commercial safety applications for the detection and measurement of flammable gases complying with the requirements of IEC 60079-29-1. This standard is applicable for oxygen measurement for the purpose of inertisation where explosion protection is provided by the exclusion of oxygen instead of measuring the combustible gases or vapours present. This standard is a compilation of practical knowledge to assist the user, and applies to apparatus, instruments and systems that indicate the presence of a flammable or potentially explosive mixture of gas or vapour with air by using an electrical signal from a gas sensor to produce a meter reading, to activate a visual or audible pre-set alarm or other device, or any combination of these. Such apparatus may be used as a means of reducing the risk whenever there is the possibility of a risk to life or property specifically due to the accumulation of a combustible gas-air mixture, by providing such warnings. It may also be used to initiate specific safety precautions (e.g. plant shutdown, evacuation, fire extinguishing procedures). This standard is applicable to all new permanent installations and, where reasonably practicable, to existing permanent installations. It is also applicable to temporary installations, whether new or existing. Similarly it is applicable to the safe use of portable or transportable apparatus, irrespective of the age or complexity of such apparatus. Since much modern apparatus of this type also includes oxygen deficiency detection and/or specific toxic gas sensors, some additional guidance is given for these topics. NOTE When in classified areas, the apparatus should be so installed and used that it is not capable of itself igniting a combustible gas-air mixture. It should therefore comply with the requirements of IEC 60079-10. For the purposes of this standard, except where specifically stated otherwise, flammable gases shall include flammable vapours. This standard applies only to group II apparatus (i.e. apparatus intended for use in industrial and commercial safety applications, involving areas classified in accordance with IEC 60079-10). For the purposes of this standard, apparatus includes a) fixed apparatus; b) transportable apparatus; and c) portable apparatus. This standard is not intended to cover, but may provide useful information, for the following: a) apparatus intended only for the detection of non-flammable toxic gases; b) apparatus of laboratory or scientific type intended only for analysis or measurement purposes; c) apparatus intended for underground mining applications (group I apparatus); d) apparatus intended only for process control applications; e) apparatus intended for applications in explosives processing and manufacture; f) apparatus intended for the detection of a potentially flammable atmosphere resulting from dust or mist in air; g) open path apparatus not used for point measurement.

BS EN 60079-29-2:2007 Referenced Document

  • IEC 60079-0 Interpretation Sheet 2 - Explosive atmospheres - Part 0: Equipment - General requirements*2019-06-27 Update
  • IEC 60079-29-1 Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases*2024-04-19 Update

BS EN 60079-29-2:2007 history

  • 2015 BS EN 60079-29-2:2015 Explosive atmospheres. Gas detectors. Selection, installation, use and maintenance of detectors for flammable gases and oxygen
  • 2008 BS EN 60079-29-2:2007 Explosive atmospheres - Part 29-2: Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen
  • 1999 BS EN 50073:1999 Guide for selection, installation, use and maintenance of apparatus for the detection and measurement of combustible gases or oxygen