This specification applies to rotating electrical machines with rated voltages (Un) from 5 kV to 24 kV inclusive and with rated output from 5 MVA upwards for generators and from 5 MW upwards for motors.
Requirements for machines with rated voltage above 24 kV should remain the subject of individual agreement.
This specification is also applicable to machines with rated outputs between 1 MVA
(1 MW) and 5 MVA (5 MW) and with rated voltages of 5 kV and above, provided its use
has been agreed beforehand.
In the case of machines whose windings are cured in the stator, tests on the separate winding elements are not possible; for these machines the requirements in Part B apply. The test of the conductor lamination insulation must however be carried out in accordance with clause 2.3 of Part A.
SIS SS 426 01 65-1979 history
1979SIS SS 426 01 65-1979 Rotating electrical machinery — Test of the insulation of bars and coils of high voltage machines