International Organization for Standardization (ISO)
Latest
ISO 12710:2002
Scope
1 This International Standard establishes the procedures for measuring performance characteristics of components of pulse-echo ultrasonic non-destructive testing instruments including both analog and digital type instruments with screen displays. The aim is to establish uniformity of evaluation techniques, to form a basis for data correlation and for interpretation of results obtained from different laboratories and at different times. Note that this International Standard establishes no acceptance criteria; such criteria should be specified by user parties.
The usual components of ultrasonic non-destructive testing instruments and the performance characteristics for which procedures for measuring these characteristics are included and listed in 1.2 to 1.6.
2 Power supply section:
— line regulation
— battery discharge time
— battery charge time
3 Pulser section:
— pulse shape
— pulse amplitude
— pulse rise time
— pulse length
— pulse frequency spectrum
4 Receiver section:
— vertical linearity
— frequency response
— noise and sensitivity
— dB controls
5 Time base section:
— horizontal linearity
— clock (pulse repetition rate)
6 Gate section/alarm section:
— delay and width
— resolution
— alarm level
— gain uniformity
— analog output
— back-echo gate linearity
ISO 12710:2002 history
2002ISO 12710:2002 Non-destructive testing - Ultrasonic inspection - Evaluation electronic characteristics of untrasonic test instruments