IEC 60079-14:2007
Explosive atmospheres - Part 14: Electrical installations design, selection and erection

Standard No.
IEC 60079-14:2007
Release Date
2007
Published By
International Electrotechnical Commission (IEC)
Status
 2013-11
Replace By
IEC 60079-14:2013
Latest
IEC 60079-14:2013/ISH2:2020
Scope
This part of IEC 60079 contains the specific requirements for the design, selection and erection of electrical installations in hazardous areas associated with explosive atmospheres. Where the equipment is required to meet other environmental conditions, for example, protection against ingress of water and resistance to corrosion, additional methods of protection may be necessary. The method used should not adversely affect the integrity of the enclosure. The requirements of this standard apply only to the use of equipment under normal or near normal atmospheric conditions. For other conditions, additional precautions may be necessary. For example, most flammable materials and many materials which are normally regarded as non-flammable might burn vigorously under conditions of oxygen enrichment. Other precautions might also be necessary in the use of equipment under conditions of extreme temperature and pressure. Such precautions are beyond the scope of this standard. These requirements are in addition to the requirements for installations in non-hazardous areas. This standard applies to all electrical equipment including fixed, portable, transportable and personal, and installations, permanent or temporary. It applies to installations at all voltages. This standard does not apply to – electrical installations in mines susceptible to firedamp; NOTE This standard may apply to electrical installations in mines where explosive gas atmospheres other than firedamp may be formed and to electrical installations in the surface installation of mines. – inherently explosive situations and dust from explosives or pyrophoric substances (for example explosives manufacturing and processing); – rooms used for medical purposes; – electrical installations in areas where the hazard is due to hybrid mixtures of combustible dust and explosive gas, vapour or mist. This standard does not take into account of any risk due to an emission of flammable or toxic gas from the dust.

IEC 60079-14:2007 history

  • 2020 IEC 60079-14:2013/ISH2:2020 Interpretation sheet 2 - Explosive atmospheres - Part 14: Electrical installations design, selection and erection
  • 2017 IEC 60079-14:2013/ISH1:2017 Explosive Atmospheres - Part 14: Electrical installations design, selection and erection; Interpretation Sheet 1
  • 2016 IEC 60079-14:2013/COR1:2016 Explosive atmospheres - Part 14: Electrical installations design, selection and erection; Corrigendum 1
  • 2013 IEC 60079-14:2013 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
  • 2007 IEC 60079-14:2007 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
  • 2002 IEC 60079-14:2002 Electrical apparatus for explosive gas atmospheres - Part 14: Electrical installations in hazardous areas (other than mines)
  • 1996 IEC 60079-14:1996 Electrical apparatus for explosive gas atmospheres - Part 14: Electrical installations in hazardous areas (other than mines)
  • 1970 IEC 60079-14:1984 Electrical apparatus for explosive gas atmospheres. Part 14: Electrical installations in explosive gas atmospheres (other than mines).
Explosive atmospheres - Part 14: Electrical installations design, selection and erection