DIN EN 60601-1-2:2007
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests (IEC 60601-1-2:2007, modified); German version EN 60601-1-2:2007

Standard No.
DIN EN 60601-1-2:2007
Release Date
2007
Published By
German Institute for Standardization
Status
Replace By
DIN EN 60601-1-2:2016
DIN EN 60601-1-2 Berichtigung 1:2010
Latest
DIN EN 60601-1-2:2022
Replace
DIN EN 60601-1-2:2006
 

DIN EN 60601-1-2:2007 Referenced Document

  • CISPR 11 Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement*2024-02-13 Update
  • CISPR 14-1 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission*2020-09-07 Update
  • CISPR 15 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment*2024-07-01 Update
  • CISPR 16-1-2 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Coupling devices for conducted disturbance measurements*2017-11-07 Update
  • CISPR 22 Interpretation sheet 3 - Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement*2012-04-27 Update
  • IEC 60417 Graphical symbols for use on equipment - 12-month subscription to regularly updated online database comprising all graphical symbols published in IEC 60417*2025-01-01 Update
  • IEC 61000-3-2 Electromagnetic compatibility (EMC) – Part 3-2: Limits – Limits for harmonic current emissions (equipment input current < 16 A per phase)*2024-03-01 Update
  • IEC 61000-3-3 Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection*2021-03-25 Update
  • IEC 61000-4-2 Electromagnetic compatibility (EMC) – Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test*2025-03-01 Update
  • IEC 61000-4-3 Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test*2020-09-08 Update
  • IEC 61000-4-4 Electromagnetic compatibility (EMC) — Part 4-4: Testing and measurement techniques — Electrical fast transient/burst immunity test*2012-04-30 Update
  • IEC 61000-4-5 Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test*2025-05-01 Update
  • IEC 61000-4-8 Electromagnetic compatibility (EMC) — Part 4-8: Testing and measurement techniques — Power frequency magnetic field immunity test*2009-09-03 Update

DIN EN 60601-1-2:2007 history

  • 2022 DIN EN 60601-1-2:2022 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests (IEC 60601-1-2:2014 + A1:2020); German version EN 60601-1-2:2015 + A1:...
  • 2017 DIN EN 60601-1-2/A1:2017-11 Draft Document - Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests (IEC 62A/1202/CD:2017)
  • 2017 DIN EN 60601-1-2/A1 E:2017 Draft Document - Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests (IEC 62A/1202/CD:2017)
  • 2016 DIN EN 60601-1-2:2016 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic disturbances - Requirements and tests (IEC 60601-1-2:2014); German version EN 60601-1-2:2015
  • 2007 DIN EN 60601-1-2:2007 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests (IEC 60601-1-2:2007, modified); German version EN 60601-1-2:2007
  • 0000 DIN EN 60601-1-2:2006
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests (IEC 60601-1-2:2007, modified); German version EN 60601-1-2:2007

Standard and Specification

DIN EN 60601-1-2 Berichtigung 1:2010 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests (IEC 60601-1-2:2007, modified); German version EN 60601 CAN/CSA-C22.2 No.60601-1-2-2008(R2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility CAN/CSA-C22.2 No.60601-1-2-2008(C2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility CSA C22.2 No.60601-1-2-03-2003 Medical electrical equipment ?Part 1-2: General requirements for safety ?Collateral standard: Electromagnetic compatibility ?Requirements and tests Edition 2.1 VDE 0750-1-6 E*DIN IEC 60601-1-6:2009-01 Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard - Usability VDE 0750-2-46 E*DIN IEC 60601-2-46:2008-04 Medical electrical equipment – Part 2-46: Particular requirements for basic safety and essential performance of operating tables VDE 0750-2-43 E*DIN IEC 60601-2-43:2008-03 Medical electrical equipment - Part 2-43: Particular requirements for the safety of X-ray equipment for interventional procedures (IEC 62B/671/CD:2007 IEC 60601-1:2005+AMD1:2012+AMD2:2020 CSV Medical electrical equipment — Part 1: General requirements for basic safety and essential performance CAN/CSA-C22.2 No.60601-2-2-2009(R2014 Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high



Copyright ©2025 All Rights Reserved