This standard specifies the method for determining the particle contamination level of phosphate ester resistant fuel oil, turbine oil, transformer oil and other auxiliary engine oil using an automatic particle counter and a microscope. This standard is suitable for measuring the particle contamination of oil products such as phosphate ester resistant fuel oil, turbine oil, transformer oil and other various auxiliary engine oils.
DL/T 432-2007 Referenced Document
GB/T 7597 Method of sampling for transformer and turbine oils in electric power industry
ISO 11171 Hydraulic fluid power — Calibration of automatic particle counters for liquids*, 2022-03-18 Update
ISO 11500 Hydraulic fluid power — Determination of the particulate contamination level of a liquid sample by automatic particle counting using the light-extinction principle*, 2022-12-21 Update
DL/T 432-2007 history
2018DL/T 432-2018 Determination method of particle size in electric power oil
2007DL/T 432-2007 Determination of particulate contamination in oil
DL/T 432-2007 Determination of particulate contamination in oil has been changed from SD 313-1989 Method for measuring particle number and size distribution in oil (automatic particle counter method).