IEC 61557-6:2007
Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 6: Effectiveness residual current devices (RCD) in TT, TN and IT systems

Standard No.
IEC 61557-6:2007
Release Date
2007
Published By
International Electrotechnical Commission (IEC)
Status
Replace By
IEC 61557-6:2019 RLV
Latest
IEC 61557-6:2019 RLV
Replace
IEC 85/279A/CDV:2006 IEC 61557-6:1997
Scope
This part of IEC 61557 specifies the requirements for measuring equipment applied to the testing of the effectiveness of protective measures by regular disconnections of residual current protective devices (RCD) in TT,TN and IT systems.

IEC 61557-6:2007 Referenced Document

  • IEC 60947-2 Low-voltage switchgear and controlgear - Part 2: Circuit-breakers
  • IEC 61008 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB's); part 2-2: applicability of the general rules to RCCB's functionally dependent on line voltage
  • IEC 61009 Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's); part 2.2: applicability of the general rules to RCBO's functionally dependent on line voltage
  • IEC 61010-1:2001 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
  • IEC 61557-1:2007 Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements

IEC 61557-6:2007 history

  • 0000 IEC 61557-6:2019 RLV
  • 2007 IEC 61557-6:2007 Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 6: Effectiveness residual current devices (RCD) in TT, TN and IT systems
  • 1997 IEC 61557-6:1997 Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 6: Residual current devices (RCD) in TT and TN systems
Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 6: Effectiveness residual current devices (RCD) in TT, TN and IT systems



Copyright ©2024 All Rights Reserved