This part of IEC 60079 specifies the requirements for the design, construction, testing and marking of electrical apparatus with type of protection increased safety "e" intended for use in explosive gas atmospheres. This standard applies to electrical apparatus with a rated value of supply voltage not exceeding 11 kV r.m.s. a.c. or d.c. Additional measures are applied to ensure that the apparatus does not produce arcs, sparks, or excessive temperatures in normal operation or under specified abnormal conditions. These specific requirements are additional to the general requirements in IEC 60079-0 that apply to type of protection increased safety "e" unless specifically excluded. 1.1DV Addition of 1.1DV: The U.S. version of IEC 60079-7 does not include requirements for Group I electrical apparatus 1.2DV Addition of 1.2DV: Where references are made to other IEC 60079 standards, the referenced requirements found in these standards shall apply as modified by any applicable U.S. National Differences.
UL 60079-7-2007 history
1970UL 60079-7-2021 Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
2017UL 60079-7 (ND)-2017 National Differences For UL 60079-7 Explosive atmospheres – Part 7: Equipment protection by increased safety ’’e’’ (Fifth Edition; Reprint with Revisions Through and Including April 21@ 2017)
2017UL 60079-7-2017 Explosive Atmospheres - Part 7: Equipment Protection by Increased Safety ''e''
2016UL 60079-7 BULLETIN-2016 "UL Standard for Safety Electrical Apparatus for Explosive Gas Atmospheres – Part 7: Increased Safety ""e"" (COMMENTS DUE: JANUARY 30@ 2017)"
2012UL 60079-7 BULLETIN-2012 "UL Standard for Safety Electrical Apparatus for Explosive Gas Atmospheres – Part 7: Increased Safety ""e"" (COMMENTS DUE: JANUARY 14@ 2013)"
2008UL 60079-7 BULLETIN-2008 "UL Standard for Safety Electrical Apparatus for Explosive Gas Atmospheres – Part 7: Increased Safety ""e"" (COMMENTS DUE: March 14@ 2008)"
2008UL 60079-7 (ND)-2008 National Differences For UL 60079-7 Explosive Atmospheres - Part 7: Equipment protection by increased safety ’e’ (Fourth Edition; Reprint with revisions through and including May 31, 2013)
2008UL 60079-7-2008 Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
2007UL 60079-7 BULLETIN-2007 "UL Standard for Safety Electrical Apparatus for Explosive Gas Atmospheres – Part 7: Increased Safety ""e"" (COMMENTS DUE: March 26@ 2007)"
2007UL 60079-7 (ND)-2007 National Differences For UL 60079-7 Electrical Apparatus for Explosive Gas Atmospheres - Part 7: Increased Safety ’e’ (Second Edition)
2007UL 60079-7-2007 Electrical apparatus for explosive gas atmospheres - Part 7: Increased safety "e"
2006UL 60079-7 BULLETIN-2006 "UL Standard for Safety Electrical Apparatus for Explosive Gas Atmospheres – Part 7: Increased Safety ""e"""
2004UL 60079-7 BULLETIN-2004 "UL Standard for Safety Electrical Apparatus for Explosive Gas Atmospheres – Part 7: Increased Safety ""e"""
2003UL 60079-7 BULLETINS-2003 "UL Standard for Safety Electrical Apparatus for Explosive Gas Atmospheres – Part 7: Increased Safety ""e"" (04/18/2003 (6p); 01/23/2003 (6p))"
2002UL 60079-7-2002 Electrical apparatus for explosive gas atmospheres - Part 7: Increased safety "e"