GB 19212.2-2006
Safety of power transformers, power supply units and similar. Part 2: Particular requirements for separating transformers for general use (English Version)

Standard No.
GB 19212.2-2006
Language
Chinese, Available in English version
Release Date
2006
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Status
 2013-05
Replace By
GB 19212.2-2012
GB/T 19212.2-2012
Latest
GB 19212.2-2012
GB/T 19212.2-2012
Scope
This chapter of GB 19212.1-2003 is replaced by the following content: This part of GB 19212 applies to stationary or mobile, single-phase or multi-phase, air-cooled, supporting or non-supporting separation transformers, whose rated power supply voltage is not For AC 1000V, the rated frequency shall not exceed 500Hz, and the rated output shall not exceed; - for single-phase transformers, 1kVA; - for multi-phase transformers, 5kVA; Transformers shall be considered as special transformers, subject to agreement between purchaser and supplier. No-load output voltage or rated output voltage shall not exceed AC 1000V or ripple-free DC 1415V. This standard applies to transformers where installation regulations and electrical codes do not require double insulation or reinforced insulation between circuits. This standard is also applicable to transformers used in conjunction with special equipment within the scope specified by relevant technical committees. This standard applies to dry-type transformers. Its windings can be hermetically sealed or unsealed.

GB 19212.2-2006 Referenced Document

  • GB 19212.1-2003 Safety of power transformers,power supply units and similar--Part 1: General requirements and tests

GB 19212.2-2006 history

  • 2012 GB 19212.2-2012 Safety of power transformers,power supplies,reactors and similar products.Part 2:Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications
  • 2006 GB 19212.2-2006 Safety of power transformers, power supply units and similar. Part 2: Particular requirements for separating transformers for general use
Safety of power transformers, power supply units and similar. Part 2: Particular requirements for separating transformers for general use

GB 19212.2-2006 -All Parts

GB 19212.1-2008 Safety of power transformers, power supplies,reactors and similar products.Part 1: General requirements and tests GB 19212.10-2014 Safety of transformers, reactors,power supply units and combinations thereof.Part 10:Particular requirements and tests for transformers and power supply units for class Ⅲ handlamps for tungsten filament lamps GB 19212.13-2005 Safety of power transformers,power supply units and similar devices.Part 13: Particular requirements for constant voltage transformers GB 19212.14-2012 Safety of transformers,reactors,power supply units and similar products for supply voltages up to 1100V.Part 14:Particular requirements and tests for auto transformers and power supply units incorporating auto transformers GB 19212.16-2005 Safety of power transformers,power supply units and similar devices.Part 16: Particular requirements for isolating transformers for supply of medical locations GB 19212.17-2013 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1100 V.Part 17 : Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units GB 19212.18-2006 Safety of power transformers, power supply units and similar. Part 18: Particular requirements for transformers for switch mode power supplies GB 19212.2-2012 Safety of power transformers,power supplies,reactors and similar products.Part 2:Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications GB 19212.20-2008 Safety of power transformers,power supply units and similar.Part 20:Particular requirements for perturbation attenuation transformers GB 19212.21-2014 Safety of transformers,reactors,power supply units and combinations thereof.Part 21:Particular requirements and tests for small reactors GB 19212.24-2005 Safety of power transformers,power supply units and similar devices.Part 24: Particular requirements for transformers for construction sites GB 19212.3-2012 Safety of power transformers,power supplies,reactors and similar products.Part 3:Particular requirements and tests for control transformers and power supplies incorporating control transformers GB 19212.4-2005 Safety of power transformers,power supply units and similar devices.Part 4: Particular requirements for ignition transformers for gas and oil burners GB 19212.5-2011 Safety of transformers,reactors,power supply units and similar products for supply voltages up to 1100 V.Part 5:Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers GB 19212.6-2013 Safety of transformers,reactors,power supply units and combinations thereof.Part 6:Particular requirements and test for transformer for shavers, power supply units for shavers and shaver supply units GB 19212.7-2012 Safety of transformers,reactors,power supply units and similar products for supply voltages up to 1100V.Part 7:Particular requirements and rest for safety isolating transformers and power supply units incorporating safety isolating transformers GB 19212.8-2012 Safety of power transformers,power supplies,reactors and similar products.Part 8:Particular requirements and tests for transformers and power supplies for toys GB 19212.9-2007 Safety of power transformers, power supply units and similar devices Part 9: Particular requirements for bell and chime transformers