This standard covers all types of manually operated high pressure oxygen line shut off valves utilizing either metallic or nonmetallic valve seats for use in general and commercial type aircraft. It is intended that the line valve should be installed in a position accessible in flight, when the cylinder mounted oxygen valves are not. The line shutoff valve may also be used optionally in large systems as a maintenance aid where only a portion of the system need be opened up and purged after repair or replacement of one or more parts. The purpose of this Aerospace Standard is to define general minimum standards for the design, fabrication, test and packaging of manually operated, high pressure oxygen line shut off valves.
SAE AS1214A-1996 history
2018SAE AS1214B-2018 Minimum Standards for Valve, High Pressure Oxygen, Line Shut Off, Manually Operated
2005SAE AS1214B-2005 Minimum Standards for Valve, High Pressure Oxygen, Line Shut Off, Manually Operated
2004SAE AS1214A-2004 Minimum Standards for Valve, High Pressure Oxygen, Line Shut Off, Manually Operated
1996SAE AS1214A-1996 Minimum Standards for Valve, High Pressure Oxygen, Line Shut Off, Manually Operated
1971SAE AS1214-1971 MINIMUM STANDARDS FOR VALVE, HIGH PRESSURE OXYGEN, LINE SHUT OFF, MANUALLY OPERATED