This International Standard specifies a method for the automated and/or manual ultrasonic testing of uncoated steel flat products for internal discontinuities by the reflection method. It is applicable to non-alloyed or alloyed steel flat products, in a nominal thickness range of 6 mm to 200 mm. However, this standard may be applied to austenitic and austenitic-ferritic steels, provided that the difference between the amplitude of the noise signal and that of the echo detection threshold is sufficient for the limit fixed. Unless otherwise agreed, for testing of steel flat products for welded steel tubes, ISO 12094 applies.
Other methods of testing (e.g. by transmission) or other test equipment may be used at the manufacturer's discretion, provided that they give identical results to those obtained under the conditions of this standard. In the event of a dispute, only the method defined in this standard will prevail.
Testing of flat products, of thickness less than 6 mm and over 200 mm, may be the subject of special agreements between the parties concerned.
The inspection is normally carried out in the place of production or on the premises of the supplier.
ISO 17577:2006 Referenced Document
ISO 12094 Welded steel tubes for pressure purposes - Ultrasonic testing for the detection of laminar imperfections in strips/plates used in the manufacture of welded tubes
ISO 9712 Non-destructive testing — Qualification and certification of NDT personnel*, 2021-12-21 Update
ISO 17577:2006 history
2016ISO 17577:2016 Steel - Ultrasonic testing of steel flat products of thickness equal to or greater than 6 mm