This European Technical Report provides guidance on assessing the possibility of inadvertent extraction
of energy from an electromagnetic field propagated from radio frequency (RF), radar or other transmitter
antennas and the coupling of this energy to an electro-explosive device (EED) in a manner capable of
causing initiation. The frequency range covered by this European Technical Report is 9 kHz to 60 GHz.
This European Technical Report only applies to bridge-wire devices which are directly initiated by radio
frequency current and does not apply to special detonators, for example, electronic detonators. It does not
cover the similar hazard arising from electromagnetic fields generated by other means, for example
electric storms, electricity generating plant or power transmission lines.
This European Technical Report does not apply to the following equipment:
− air bag igniters for automotive applications (including the igniters before they are fitted);
− special pyrotechnic devices;
− pyromechanisms;
− igniters for fireworks;
− special military devices;
− special safety equipment.
PD CLC/TR 50426:2004 history
0000 PD CLC/TR 50426:2004(2005)
2005PD CLC/TR 50426:2004 Assessment of inadvertent initiation of bridge wire electro-explosive devices by radio-frequency radiation - Guide