DIN EN 14394:2006
Heating boilers - Heating boilers with forced draught burners - Nominal heat output not exceeding 10 MW and maximum operating temperature of 110 °C; German version EN 14394:2005

Standard No.
DIN EN 14394:2006
Release Date
2006
Published By
German Institute for Standardization
Status
 2008-12
Replace By
DIN EN 14394:2008
Latest
DIN EN 14394:2008-12
Scope
This European Standard specifies the requirements and test methods for the construction, the safety and the rational energy usage for heating boilers (standard-heating and Iow temperature boilers) fired by liquid fuels from steel and cast iron with burners according to the relevant burner standards (for atomising oil burners, see. EN 267) up to a nominal heat output of 10 MW. They are operated, either with negative pressure (natural draught boiler) or with positive pressure (pressurised boiler) in the combustion chamber, in accordance with the boiler manufacturer's instructions Boilers in accordance with this European Standard are designed for the heating of central heating installations in which the heat carrier is water, and the maximum allowable operating temperature of which is up to 110 ℃ and the maximum safety temperature limiter of 120 ℃. The maximum allowable operating pressure is 10 bar. This standard does not apply to gas boilers with atmospheric burners, boilers for solid fuels, oil or gas fired condensation boilers, boilers with oil vaporisation burners. For these boilers there are further requirements. For gas-fired central heating boilers equipped with a forced draught burner of nominal heat out put not exceeding 1000 kW, see prEN 303-7. For shell boilers with a nominal heat output exceeding 10 MW and a maximum safety temperature limiter exceeding 120 ℃, see EN 12953 series. NOTE Definitions for heating boiler and Iow temperature boiler see Council Directive 92/42/EEC.

DIN EN 14394:2006 history

  • 2008 DIN EN 14394:2008-12 Heating boilers - Heating boilers with forced draught burners - Nominal heat output not exceeding 10 MW and maximum operating temperature of 110 °C; German version EN 14394:2005+A1:2008
  • 2008 DIN EN 14394:2008 Heating boilers - Heating boilers with forced draught burners - Nominal heat output not exceeding 10 MW and maximum operating temperature of 110 °C(includes Amendment A1:2008); English version of DIN EN 14394:2008-12
  • 2006 DIN EN 14394:2006 Heating boilers - Heating boilers with forced draught burners - Nominal heat output not exceeding 10 MW and maximum operating temperature of 110 °C; German version EN 14394:2005
  • 1970 DIN EN 14394 E:2002-03 Heating boilers - Heating boilers with forced draught burners - Nominal heat output not exceeding 10 MW and maximum operating temperature of 110 °C



Copyright ©2024 All Rights Reserved