This standard specifies the selection of appropriate test methods from among those available for the measurement of gaseous pollutants in compressed air. Specifies sampling, measurement, evaluation, uncertainty, and test reporting for applicable gaseous pollutants carbon monoxide, carbon dioxide, sulfur dioxide, nitrogen monoxide, nitrogen dioxide, and hydrocarbons C to C. (For C and above, refer to JIS B 8392-5). The specified method can also be applied to other gases.
JIS B 8392-6:2006 Referenced Document
JIS B 0125-1 Fluid power systems and components -- Graphical symbols and circuit diagrams -- Part 1: Graphical symbols for conventional use and data-processing applications*, 2020-01-01 Update
JIS B 8392-1 Compressed air.Part 1: Contaminants and purity classes*, 2012-11-20 Update
JIS Z 8202-0 Quantities and units -- Part 0: General principles
JIS Z 8202-3 Quantities and units -- Part 3: Mechanics
JIS Z 9041-2 Statistical interpretation of data Part 2: Techniques of estimation and test relating to means and variances
JIS B 8392-6:2006 history
2006JIS B 8392-6:2006 Compressed air -- Part 6: Test methods for gaseous contaminant content