IEC 61000-4-5:2005
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test

Standard No.
IEC 61000-4-5:2005
Release Date
2005
Published By
International Electrotechnical Commission (IEC)
Status
 2014-05
Replace By
IEC 61000-4-5/Cor:2009
Latest
IEC 61000-4-5:2014/AMD1:2017
Scope
This part of GB/T 17626 specifies the equipment's immunity requirements, test methods and recommended test level range for unipolar surges (impacts) caused by switching and lightning transient overvoltage, and specifies different environments and installations. Several test levels in the state. The requirements set forth in this section apply to electrical and electronic equipment. The purpose of this section is to establish a common benchmark for evaluating the performance of electrical and electronic equipment when subjected to surges (shocks). This standard specifies a consistent test method for evaluating the immunity of equipment or systems to specified phenomena. Note: According to GB/Z18509-'2001, this part is the basic electromagnetic compatibility standard for use by various product committees. GB/Z 18509...-2001 also stipulates that the product committee is responsible for determining whether to apply this immunity test standard. If used, it should also be responsible for determining the appropriate test level and performance criteria. The National Technical Committee on Electromagnetic Compatibility Standardization and its sub-technical committees are willing to cooperate with product committees to evaluate the special immunity requirements of their products. This part specifies:  ——the range of test levels;  ——test equipment;  ——test configuration;  ——test procedures. The task of the laboratory test is to find out the response of the equipment to a surge (impulse) voltage with a certain harmful level generated by switching or lightning when operating under specified working conditions. This section does not test the high-voltage insulation capability of the equipment under test. This section does not consider the direct injection of lightning current from direct lightning strikes.

IEC 61000-4-5:2005 history

  • 2017 IEC 61000-4-5:2014/AMD1:2017 Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
  • 2017 IEC 61000-4-5:2017 Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
  • 2014 IEC 61000-4-5:2014 Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
  • 2009 IEC 61000-4-5:2005/COR1:2009 Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test; Corrigendum 1
  • 2009 IEC 61000-4-5/Cor:2009 Electromagnetic compatibility (EMC) – Part 4-5: Testing and measurement techniques – Surge immunity test (Edition 2.0)
  • 2005 IEC 61000-4-5:2005 Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
  • 2001 IEC 61000-4-5:2001 Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques; Surge immunity test
  • 1970 IEC 61000-4-5:1995/AMD1:2000 Amendment 1 - Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 5: Surge immunity test
  • 1995 IEC 61000-4-5:1995/COR1:1995 Corrigendum 1 — Electromagnetic compatibility (EMC)- Part 4-5: Testing and measurement techniques — Surge immunity test
  • 1995 IEC 61000-4-5:1995 Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 5: Surge immunity test
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test