Scope
This European Standard specifies the performance requirements and test methods for non-biological indicator systems, including the process challenge devices within which they are intended to function, to be used for testing the steam penetration performance of small steam sterilizers, Type B or Type S where appropriate. The test systems specified are intended for use only in small steam sterilizers Type B conforming to prEN 13060-2 and having a usable chamber space greater than 10I and for small steam sterilizers Type S conforming to prEN 13060-4 also having a usable chamber space greater than 5I. Non-biological indicator systems and the associate process challenge devices are specified for various types of load. The possible loads are considered in two classes: Porous loads, which can be wrapped or unwrapped, or hollow instrument loads, which also can be wrapped or unwrapped. The relevant section of this European Standard on porous loads specifies the requirements for: - a standard process challenge device to be used in the small load test for porous loads in small steam sterilizers; - an indicator system for use in the porous load process challenge device. An indicator for this purpose is a Class B indicator as described in EN 867-1. - an indicator employing an alternative process challenge device equivalent to the porous load process challenge device. The relevant section of this European Standard on hollow instruments specifies the requirements for: - hollow load process challenge devices to be used to simulate hollow instrument loads as defined in prEN 13060-4; - an indicator system, for use in one of the hollow load process challenge device, for assessing steam penetration in a wrapped load of hollow instruments. An indicator for this purpose is a Class B indicator as described in EN 867-1. The process challenge devices described in this standard are intended for use only in sterilizers of sufficient size to accommodate the process challenge device with no part of the process challenge device closer than 20 mm from the vessel wall; in the case of the porous load process challenge device the total internal volume of the vessel is not less than 10I

BS EN 867-5:2001 history

  • 2001 BS EN 867-5:2001 Non-biological systems for use in sterilizers - Specification for indicator systems and process challenge devices for use in performance testing for small sterilizers Type B and Type S
Non-biological systems for use in sterilizers - Specification for indicator systems and process challenge devices for use in performance testing for small sterilizers Type B and Type S



Copyright ©2024 All Rights Reserved