This part of IEC 60534 applies to the following control valves:
- types: segmented ball and eccentric rotary control valves with or without flanges;
- nominal sizes: DN20 up to and including DN400;
NOTE 1 See ISO 7005 and ISO 6708.
- designations: PN10, PN16, PN20, PN25, PN40, PN50, PN63, PN100 and PN110.
NOTE 2 See ISO 7005 and ISO 7268.
NOTE 3 Designations PN63 and PN100 are not included in ISO 7005.
NOTE 4 Designations PN20, PN50 and PN110 are not included in European Standard EN 1092.
NOTE 5 For the purposes of face-to-face dimensions, designation PN100 in EN 1092 corresponds to PN110.
NOTE 6 For the purposes of face-to-face dimensions, the following correlations apply:
- PN20 covers Classes 125 and 150 in the ANSI system;
- PN50 covers Classes 250 and 300 in the ANSI system;
- PN110 covers Class 600 in the ANSI system.
Only raised face flanges are covered.
Specifically excluded from this standard are all valves having welded or threaded end connections.
IEC 60534-3-2:2001 history
2001IEC 60534-3-2:2001 Industrial-process control valves - Part 3-2: Dimensions; Face-to-face dimensions for rotary control valves except butterfly valves
1984IEC 60534-3-2:1984 Industrial-process control valves.. Part 3 : Dimensions. Section Two : Face-to-face dimensions for flangeless control valves except wafer butterfly valves.